Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STATURE ELECTRIC INC DIV ALLIED MOTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STATURE ELECTRIC INC DIV ALLIED MOTION in 22543 FISHER ROAD, WATERTOWN, NY 13601 (NAICS 335312). OSHA activity number 312368947.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stature Electric INC DIV Allied Motion — free Get an email when a new federal OSHA severe-injury report for Stature Electric INC DIV Allied Motion is published. One employer, no account, unsubscribe in one click.
Site address
22543 FISHER ROAD
City
WATERTOWN
State
NY
ZIP
13601
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335312
SIC code (legacy)
3621
Employees
58
Ownership type
A
Industry flags
Manufacturing safety.

22 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 4 instances 4 exposed
Issued
May 7, 2009
Abate by
Jun 9, 2009
Penalty
Initial $875 · Current $525 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to THE HAZARD OF BEING STRUCK-BY:
a)Loading Dock, on or about 04/16/09, A Demag 1 ton overhead electric hoist
had the upper and lower limit safety switch improperly adjusted that did
not
function in accordance with the manufacturer's manual and no recorded
annual inspection had been conducted.
b)Heavy Duty area, on or about 04/16/09, A Dayton 1/2 ton overhead electric
hoist had the upper and lower limit safety switch improperly adjusted that
did not function in accordance with the manufacturer's manual and no
recorded annual inspection had been conducted.
Among other methods, several feasible and acceptable abatement methods to
correct
these hazards are to:
1.Repair or replace the lower limit switches and ensure they are
adjusted to meet the requirement of the manufacturer's operation
manual, Checking limit switch operation and ANSI B30.16 1973-1993,
Overhead Hoists, Section 16, Adjustments, Repairs, and
Replacements.
2.Conduct frequent and periodic inspections of the hoists in accordance
with the manufacturer's manual and ANSI B30.16 1973-1993
Overhead Hoists, Section 16, Inspection.
c)Loading dock, on or about 04/16/09, a locally fabricated below-the-hook
spreader bar was being used to hoist material and no initial capacity
rating,
marked on the bar, and no recorded annual inspection had been conducted.
Among other methods, feasible and acceptable methods to correct each of
this
hazard is to:
1.Rate and mark the load capacity of all below-the-hook lifting devices
on a tag/plate or equivalent in accordance with ASME B30.20-1993,
Chapter 20-3.
2.Conduct frequent and periodic inspections of the lifting device in
accordance with ASME B30.20-1993, Chapter 20-4.
d)Heavy duty area, on or about 04/16/09, The monorail beam used to support
a Dayton hoist was being used to hoist material and had not been
initialtested, rated, and marked on the rail, and no recorded annual
inspection had
been conducted.
Among other methods, feasible and acceptable methods to correct each of
this
hazard is to:
1.Rate and mark the load capacity of all monorail beams used for
hoisting on a tag/plate or equivalent in accordance with ASME
B30.11-1980, Chapter 11-1.
2.Conduct frequent and periodic inspections of the monorail system in
accordance with ASME B30.11-1980, Chapter 11-2.
Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $875.00

1910.37 B04

Serious Gravity 03 1 instance 18 exposed
Issued
May 7, 2009
Abate by
Jun 25, 2009
Penalty
Initial $875 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $875.00

1910.37 B05

Serious Gravity 03 1 instance 16 exposed
Issued
May 7, 2009
Abate by
Jun 25, 2009
Recent events (2)
  • — I (S)
  • — Z (S)

1910.106 H03 IB

Serious Gravity 03 5 instances 11 exposed
Issued
May 7, 2009
Abate by
Aug 10, 2009
Penalty
Initial $875 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $875.00

1910.106 H04 IVA

Serious Gravity 03 6 instances 11 exposed
Issued
May 7, 2009
Abate by
Aug 10, 2009
Recent events (2)
  • — I (S)
  • — Z (S)

1910.106 H07 IB

Serious Gravity 03 6 instances 11 exposed
Issued
May 7, 2009
Abate by
Aug 10, 2009
Recent events (2)
  • — I (S)
  • — Z (S)

1910.106 H08 I

Serious Gravity 03 3 instances 15 exposed
Issued
May 7, 2009
Abate by
Aug 10, 2009
Recent events (2)
  • — I (S)
  • — Z (S)

1910.107 L01

Serious Gravity 03 1 instance 11 exposed
Issued
May 7, 2009
Abate by
Nov 10, 2009
Penalty
Initial $875 · Current $525 Reduced
Recent events (3)
  • — P (S) $525.00
  • — I (S) $525.00
  • — Z (S) $875.00

1910.107 L02 II

Serious Gravity 03 1 instance 11 exposed
Issued
May 7, 2009
Abate by
Nov 10, 2009
Recent events (3)
  • — P (S)
  • — I (S)
  • — Z (S)

1910.107 L04 I

Serious Gravity 03 1 instance 11 exposed
Issued
May 7, 2009
Abate by
Nov 10, 2009
Recent events (3)
  • — P (S)
  • — I (S)
  • — Z (S)

1910.107 L04 III

Serious Gravity 03 1 instance 11 exposed
Issued
May 7, 2009
Abate by
Aug 10, 2009
Recent events (2)
  • — I (S)
  • — Z (S)

1910.151 C

Serious Gravity 03 1 instance 3 exposed
Issued
May 7, 2009
Abate by
Aug 10, 2009
Penalty
Initial $875 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $875.00

1910.212 A01

Serious Gravity 03 17 instances 11 exposed
Issued
May 7, 2009
Abate by
Aug 10, 2009
Penalty
Initial $875 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $875.00

1910.215 A04

Serious Gravity 02 1 instance 10 exposed
Issued
May 7, 2009
Abate by
May 12, 2009
Penalty
Initial $700 · Current $420 Reduced
Recent events (2)
  • — I (S) $420.00
  • — Z (S) $700.00

1910.215 B09

Serious Gravity 02 1 instance 10 exposed
Issued
May 7, 2009
Abate by
May 12, 2009
Recent events (2)
  • — I (S)
  • — Z (S)

1910.219 D01

Serious Gravity 02 4 instances 7 exposed
Issued
May 7, 2009
Abate by
Jun 25, 2009
Penalty
Initial $700 · Current $420 Reduced
Recent events (2)
  • — I (S) $420.00
  • — Z (S) $700.00

1910.219 E03 I

Serious Gravity 02 2 instances 7 exposed
Issued
May 7, 2009
Abate by
Jun 25, 2009
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 B02

Serious Gravity 03 5 instances 4 exposed
Issued
May 7, 2009
Abate by
May 12, 2009
Penalty
Initial $875 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $875.00

1910.305 G01 IVA

Serious Gravity 03 4 instances 10 exposed
Issued
May 7, 2009
Abate by
Jun 9, 2009
Recent events (2)
  • — I (S)
  • — Z (S)

1910.304 G05

Serious Gravity 03 1 instance 9 exposed
Issued
May 7, 2009
Abate by
May 12, 2009
Penalty
Initial $875 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $875.00

1910.147 C06 I

Other-than-serious Gravity 01 1 instance 18 exposed
Issued
May 7, 2009
Abate by
Jun 25, 2009
Recent events (2)
  • — I (O)
  • — Z (O)

1910.212 A03 II

Serious Gravity 03 1 instance 11 exposed
Issued
May 1, 2009
Abate by
Jun 3, 2009
Penalty
Initial $875 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $875.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312368947.