WATERTOWN, NY —
OSHA Inspection: STATURE ELECTRIC INC DIV ALLIED MOTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STATURE ELECTRIC INC DIV ALLIED MOTION in 22543 FISHER ROAD, WATERTOWN, NY 13601 (NAICS 335312). OSHA activity number 312368947.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STATURE ELECTRIC INC DIV ALLIED MOTION
- Site address
- 22543 FISHER ROAD
- City
- WATERTOWN
- State
- NY
- ZIP
- 13601
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335312
- SIC code (legacy)
- 3621
- Employees
- 58
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
22 citations on file for this inspection.
5(a)(1)
- Issued
- May 7, 2009
- Abate by
- Jun 9, 2009
- Penalty
- Initial $875 · Current $525 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY: a)Loading Dock, on or about 04/16/09, A Demag 1 ton overhead electric hoist had the upper and lower limit safety switch improperly adjusted that did not function in accordance with the manufacturer's manual and no recorded annual inspection had been conducted. b)Heavy Duty area, on or about 04/16/09, A Dayton 1/2 ton overhead electric hoist had the upper and lower limit safety switch improperly adjusted that did not function in accordance with the manufacturer's manual and no recorded annual inspection had been conducted. Among other methods, several feasible and acceptable abatement methods to correct these hazards are to: 1.Repair or replace the lower limit switches and ensure they are adjusted to meet the requirement of the manufacturer's operation manual, Checking limit switch operation and ANSI B30.16 1973-1993, Overhead Hoists, Section 16, Adjustments, Repairs, and Replacements. 2.Conduct frequent and periodic inspections of the hoists in accordance with the manufacturer's manual and ANSI B30.16 1973-1993 Overhead Hoists, Section 16, Inspection. c)Loading dock, on or about 04/16/09, a locally fabricated below-the-hook spreader bar was being used to hoist material and no initial capacity rating, marked on the bar, and no recorded annual inspection had been conducted. Among other methods, feasible and acceptable methods to correct each of this hazard is to: 1.Rate and mark the load capacity of all below-the-hook lifting devices on a tag/plate or equivalent in accordance with ASME B30.20-1993, Chapter 20-3. 2.Conduct frequent and periodic inspections of the lifting device in accordance with ASME B30.20-1993, Chapter 20-4. d)Heavy duty area, on or about 04/16/09, The monorail beam used to support a Dayton hoist was being used to hoist material and had not been initialtested, rated, and marked on the rail, and no recorded annual inspection had been conducted. Among other methods, feasible and acceptable methods to correct each of this hazard is to: 1.Rate and mark the load capacity of all monorail beams used for hoisting on a tag/plate or equivalent in accordance with ASME B30.11-1980, Chapter 11-1. 2.Conduct frequent and periodic inspections of the monorail system in accordance with ASME B30.11-1980, Chapter 11-2. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.37 B04
- Issued
- May 7, 2009
- Abate by
- Jun 25, 2009
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.37 B05
- Issued
- May 7, 2009
- Abate by
- Jun 25, 2009
Recent events (2)
- — I (S)
- — Z (S)
1910.106 H03 IB
- Issued
- May 7, 2009
- Abate by
- Aug 10, 2009
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.106 H04 IVA
- Issued
- May 7, 2009
- Abate by
- Aug 10, 2009
Recent events (2)
- — I (S)
- — Z (S)
1910.106 H07 IB
- Issued
- May 7, 2009
- Abate by
- Aug 10, 2009
Recent events (2)
- — I (S)
- — Z (S)
1910.106 H08 I
- Issued
- May 7, 2009
- Abate by
- Aug 10, 2009
Recent events (2)
- — I (S)
- — Z (S)
1910.107 L01
- Issued
- May 7, 2009
- Abate by
- Nov 10, 2009
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (3)
- — P (S) $525.00
- — I (S) $525.00
- — Z (S) $875.00
1910.107 L02 II
- Issued
- May 7, 2009
- Abate by
- Nov 10, 2009
Recent events (3)
- — P (S)
- — I (S)
- — Z (S)
1910.107 L04 I
- Issued
- May 7, 2009
- Abate by
- Nov 10, 2009
Recent events (3)
- — P (S)
- — I (S)
- — Z (S)
1910.107 L04 III
- Issued
- May 7, 2009
- Abate by
- Aug 10, 2009
Recent events (2)
- — I (S)
- — Z (S)
1910.151 C
- Issued
- May 7, 2009
- Abate by
- Aug 10, 2009
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.212 A01
- Issued
- May 7, 2009
- Abate by
- Aug 10, 2009
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.215 A04
- Issued
- May 7, 2009
- Abate by
- May 12, 2009
- Penalty
- Initial $700 · Current $420 Reduced
Recent events (2)
- — I (S) $420.00
- — Z (S) $700.00
1910.215 B09
- Issued
- May 7, 2009
- Abate by
- May 12, 2009
Recent events (2)
- — I (S)
- — Z (S)
1910.219 D01
- Issued
- May 7, 2009
- Abate by
- Jun 25, 2009
- Penalty
- Initial $700 · Current $420 Reduced
Recent events (2)
- — I (S) $420.00
- — Z (S) $700.00
1910.219 E03 I
- Issued
- May 7, 2009
- Abate by
- Jun 25, 2009
Recent events (2)
- — I (S)
- — Z (S)
1910.303 B02
- Issued
- May 7, 2009
- Abate by
- May 12, 2009
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.305 G01 IVA
- Issued
- May 7, 2009
- Abate by
- Jun 9, 2009
Recent events (2)
- — I (S)
- — Z (S)
1910.304 G05
- Issued
- May 7, 2009
- Abate by
- May 12, 2009
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
1910.147 C06 I
- Issued
- May 7, 2009
- Abate by
- Jun 25, 2009
Recent events (2)
- — I (O)
- — Z (O)
1910.212 A03 II
- Issued
- May 1, 2009
- Abate by
- Jun 3, 2009
- Penalty
- Initial $875 · Current $525 Reduced
Recent events (2)
- — I (S) $525.00
- — Z (S) $875.00
More inspections in this industry (NAICS 335312)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312368947.