WATERTOWN, NY —
OSHA Inspection: METAL MAN SERVICES, DIV. OF KENAL SERVICES CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of METAL MAN SERVICES, DIV. OF KENAL SERVICES CORP. in 1109 WATER STREET, WATERTOWN, NY 13601 (NAICS 332323). OSHA activity number 312370349.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- METAL MAN SERVICES, DIV. OF KENAL SERVICES CORP.
- Site address
- 1109 WATER STREET
- City
- WATERTOWN
- State
- NY
- ZIP
- 13601
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- SIC code (legacy)
- 3446
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 14, 2009
- Abate by
- Sep 16, 2009
- Penalty
- Initial $750 · Current $488 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY: a)Steel storage area, on or about 07/22/2009, a Coffing 1-ton overhead electric hoist had a hook safety latch removed, the lower limit safety switch did not function in accordance with the manufacturer's manual and no recorded annual inspection had been conducted. b)Steel storage area, on or about 07/22/2009, a Lynx 1-ton overhead electric hoist had the hook safety latch removed, the lower limit safety switch did not function in accordance with the manufacturer's manual and no recorded annual inspection had been conducted. c)Accupress area, on or about 07/22/2009, A Lynx 1-ton overhead electric hoist had a lower limit safety switch that did not function in accordance with the manufacturer's manual and no recorded annual inspection had been conducted. Among other methods, several feasible and acceptable abatement methods to correct this hazard are to: 1.Repair or replace the safety latch and ensure the Safety limit switches are adjusted to meet the requirement of the manufacturer's operation manual, Section: Checking Limit switch operation and ANSI B30.16.-1993, Overhead Hoists, Section 16.2, Adjustments, Repairs, and Replacements. 2.Conduct frequent and periodic inspections of the hoists in accordance with ANSI B30.16-1973-1993 Overhead Hoists, Section 16-2.1 Inspection. d)Steel Storage area, on or about 07/22/2009, The two (2) Overhead hoist monorails did not have rated load tests conducted and maintained on file and no recorded annual inspection had been conducted and maintained. e)Accupress area, on or about 07/22/2009, One (1) Overhead hoist monorail did not have a rated load test conducted and maintained on file and no recorded annual inspection had been conducted and maintained. Among other methods, several feasible and acceptable abatement methods to correct these hazards are to: 1.Conduct a rated load test of the monorail and maintain the test reports on file in accordance with ANSI B30.11-1980, Section 11-2, Rated Load test.2.Conduct frequent and periodic inspections of hoist monorail systems and maintain records in accordance with ANSI B30.11-1973 Monorail Systems and Underhung Cranes, Section 11-2 Inspection, Testing, and Maintenance. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $487.50
- — Z (S) $750.00
1910.147 C01
- Issued
- Aug 14, 2009
- Abate by
- Aug 19, 2009
- Penalty
- Initial $750 · Current $488 Reduced
Recent events (2)
- — I (S) $487.50
- — Z (S) $750.00
1910.212 A01
- Issued
- Aug 14, 2009
- Abate by
- Aug 19, 2009
- Penalty
- Initial $750 · Current $488 Reduced
Recent events (2)
- — I (S) $487.50
- — Z (S) $750.00
1910.212 A03 II
- Issued
- Aug 14, 2009
- Abate by
- Aug 19, 2009
- Penalty
- Initial $750 · Current $488 Reduced
Recent events (2)
- — I (S) $487.50
- — Z (S) $750.00
1910.305 G01 IVA
- Issued
- Aug 14, 2009
- Abate by
- Aug 19, 2009
- Penalty
- Initial $750 · Current $488 Reduced
Recent events (2)
- — I (S) $487.50
- — Z (S) $750.00
More inspections at Metal MAN Services, DIV. of Kenal Services Corp.
View Metal MAN Services, DIV. of Kenal Services Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332323)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312370349.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.