CUSHING, OK —
OSHA Inspection: J & C CASING PULLERS & PLUGGING LLC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of J & C CASING PULLERS & PLUGGING LLC in 403 N HARMON ROAD, CUSHING, OK 74023 (NAICS 213112). OSHA activity number 312376908.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & C CASING PULLERS & PLUGGING LLC
- Site address
- 403 N HARMON ROAD
- City
- CUSHING
- State
- OK
- ZIP
- 74023
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- SIC code (legacy)
- 1389
- Employees
- 6
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 10, 2009
- Abate by
- Mar 5, 2009
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to the hazard of uncontrolled release of potentially volatile gas and/or liquid from the well. Reference: American Petroleum Institute, Recommended Practice 54; Sec. 6.4.1 For the employees working on the service rig on or about August 27th, 2008. The employer did not ensure blow out prevention equipment was installed on the well when natural gas was found to be flowing upon opening of the well.
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
1910.132 D01
- Issued
- Feb 10, 2009
- Abate by
- Mar 5, 2009
- Penalty
- Initial $2,000
Recent events (2)
- — I (S)
- — Z (S) $2000.00
5(a)(1)
- Issued
- Feb 10, 2009
- Abate by
- Mar 5, 2009
- Penalty
- Initial $14,000 · Current $13,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to the hazard of not having immediate access to a secondary means of escape, in the event of an emergency. Referenced in the American Petroleum Institute, Recommended Practice No. 54, Sec. 6.10.1. For the employee working in the derrick on or about August 27th, 2008. The employer did not provide an emergency escape device. Exposing employees to the hazard of becoming trapped in the derrick in an emergency, causing thermal or chemical burns or death.
Recent events (2)
- — I (W) $13000.00
- — Z (W) $14000.00
5(a)(1)
- Issued
- Feb 10, 2009
- Abate by
- Mar 5, 2009
- Penalty
- Initial $14,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed the potential hazard of thermal and/or chemical burns from the uncontrolled discharge of volatile gasses and/or liquids. Reference: Oklahoma Corporation Commission Regulation; OAC 165:10-11-6(e) For the employees working on the service rig on or about August 27th, 2008. The employer did not ensure volatile gases and/or liquids in the well were displaced with an inert material before performing work on the well. Employees were exposed to gas and liquid escaping from the well causing thermal burns.
Recent events (2)
- — I (W)
- — Z (W) $14000.00
More inspections in this industry (NAICS 213112)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312376908.