SALISBURY, NC —
OSHA Inspection: SUPERIOR WALLS SYSTEMS, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SUPERIOR WALLS SYSTEMS, LLC in 3570 S. MAIN STREET, SALISBURY, NC 28147 (NAICS 444190). OSHA activity number 312414170.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPERIOR WALLS SYSTEMS, LLC
- Site address
- 3570 S. MAIN STREET
- City
- SALISBURY
- State
- NC
- ZIP
- 28147
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- SIC code (legacy)
- 5211
- Employees
- 89
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
38 citations on file for this inspection.
95012901
- Issued
- Aug 25, 2008
- Abate by
- Sep 5, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by/crushing hazard while operating forklifts: a)facility, forklift trucks were installed with an overhead guard, but seat belts were not worn by forklift operators, exposing them to a struck-by hazard in the event of forklift overturning. Among other methods, one feasible and acceptable method to correct this hazard is to require employees to wear seat belts when operating forklift trucks. Reference: American Society of Mechanical Engineers, Safety Standard for Low Lift and High Lift Trucks, ASME B56.1-1993, paragraph 5.3.19: An active operator protection device or system, when provided, shall be used.
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
95012901
- Issued
- Aug 25, 2008
- Abate by
- Sep 3, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fall hazard while securing the load on to a trailer: a)production, no fall protection was provided for the employee who climbed onto the top of concrete wall forms to install cardboard and strapping so that it could be secured to the trailer for shipment. The employee was exposed to a fall hazard of up to 14-feet to the concrete floor below. Among other methods, one feasible and acceptable method to abate this hazard is to ensure that employees not climb onto the load while securing it. The operation could be completed by utilizing an extension ladder to reach the center tie down and securing it.
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.146 C01
- Issued
- Aug 25, 2008
- Abate by
- Sep 3, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.146 C02
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.146 C04
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
- Penalty
- Initial $875 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $875.00
1910.146 D03
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
1910.146 E01
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
1910.146 G01
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
1910.147 C01
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
- Penalty
- Initial $1,250 · Current $875 Reduced
Recent events (2)
- — I (S) $875.00
- — Z (S) $1250.00
1910.177 C01
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.177 D02
- Issued
- Aug 25, 2008
- Abate by
- Sep 5, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.177 D04
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.177 G
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.178 L01 I
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.179 B03
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.179 J01 I
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.212 A03 II
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.305 B01 II
- Issued
- Aug 25, 2008
- Abate by
- Sep 3, 2008
- Penalty
- Initial $1,750 · Current $1,225 Reduced
Recent events (2)
- — I (S) $1225.00
- — Z (S) $1750.00
1910.23 B01 I
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.23 E01
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.37 B05
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.101 B
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.110 E04 III
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.134 C01
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
1910.134 E01
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.134 F02
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.134 K03
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.178 Q07
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.184 E03 II
- Issued
- Aug 25, 2008
- Abate by
- Sep 3, 2008
1910.253 B04 I
- Issued
- Aug 25, 2008
- Abate by
- Sep 5, 2008
1910.303 F02
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
1910.304 G05
- Issued
- Aug 25, 2008
- Abate by
- Sep 5, 2008
1910.305 B02
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.305 G01 IVA
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.305 G02 III
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.1200 E01
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
1910.1200 F05 I
- Issued
- Aug 25, 2008
- Abate by
- Sep 19, 2008
1910.1200 H01
- Issued
- Aug 25, 2008
- Abate by
- Oct 10, 2008
More inspections at Superior Walls Systems, LLC
View Superior Walls Systems, LLC's full OSHA safety record →
More inspections in this industry (NAICS 444190)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312414170.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.