BUFFALO, NY —
OSHA Inspection: NFTA POLICE DEPT RAIL DETAIL
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NFTA POLICE DEPT RAIL DETAIL in 1404 MAIN ST, BUFFALO, NY 14209 (NAICS 482111). OSHA activity number 312468077.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NFTA POLICE DEPT RAIL DETAIL
- Site address
- 1404 MAIN ST
- City
- BUFFALO
- State
- NY
- ZIP
- 14209
- Mailing
- 181 ELLICOTT ST, BUFFALO, NY 14205
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 482111
- SIC code (legacy)
- 4011
- Employees
- 55
- Ownership type
- B
Citations
4 citations on file for this inspection.
3A0001
- Issued
- Aug 29, 2012
- Abate by
- Nov 26, 2012
General-duty citation text
NYSLL Article 2, Section 27-a.3.a(1): The employer did not furnish to each of its employees, employment and a place of employment which was free from recognized hazards that are causing or were likely to cause death or serious physical harm to its employees and which will provide reasonable and adequate protection to the lives, safety or health of its employees. In applying this paragraph, fundamental distinctions between private and public employment have been recognized. a)The employer did not keep the workplace free of a recognized hazard to which employees of that employer were exposed. In the NFTA Police Department offices, employees were not protected from pieces of plaster falling from the edges of an upper ceiling, through a drop ceiling, into the first floor office space used regularly by employees. Pieces of plaster up to 12in by 12in by 3/4in have fallen from around the edges of the upper ceiling through the drop ceiling into work areas, most recently on 5/29/12. This exposes employees to the hazard of being struck by pieces of plaster falling about 25ft. There are no OSHA or PESH standards which address this specific hazard. The hazard was recognized. Large pieces of plaster falling into work areas are obvious hazards to employees. Also, the Police Chief stated he has been aware of the issue and stated that the employer has come up with a plan for abatement. The implementation of this plan is being expedited due to the most recent incident, although no protective measures had been put in place at the time of the inspection. The hazard was likely to cause death or serious physical injury including, but not limited to: contusions, concussions, lacerations, etc. as a result of pieces of plaster falling from the upper ceiling, through the drop ceiling into the workplace and striking employees. While the drop ceiling has prevented some smaller pieces of plaster from reaching the floor, pieces of plaster up to 12in by 12in by 3/4in have fallen from around the perimeter edges of the upper ceiling, piercing the drop ceiling and falling into work areas. Pieces of plaster large enough to fall through the drop ceiling have fallen 3 times in the past year, most recently on 5/29/12. Reasonable and adequate abatement methods are readily available to eliminate the hazard. Feasible means of abatement include, but are not limited to, placing netting across the open areas above the drop ceiling to catch any pieces of falling plaster or repairing and/or replacing damaged plaster in affected areas. At the time of the inspection, the Police Chief stated that the NFTA Engineering Department already has a plan which will abate the hazard. Only the perimeter edges of the plaster ceiling had been affected at the time of the inspection. The center of the upper ceiling was intact. The employer representative stated that they have been advised that the natural expansion and contraction of the building is what caused the plaster to fall from around the edges.
1910.303 F02
- Issued
- Aug 29, 2012
- Abate by
- Oct 15, 2012
1910.304 G06 VIC
- Issued
- Aug 29, 2012
- Abate by
- Oct 1, 2012
1910.305 B02 I
- Issued
- Aug 29, 2012
- Abate by
- Sep 17, 2012
More inspections at Nfta Police Dept Rail Detail
View Nfta Police Dept Rail Detail's full OSHA safety record →
More inspections in this industry (NAICS 482111)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312468077.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.