Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: A.J. STOVES & PELLETS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A.J. STOVES & PELLETS, LLC in 5773 COLORADO STREET, MARION, PA 17235 (NAICS 321999). OSHA activity number 312508047.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A.J. Stoves & Pellets, LLC for free Get an email when a new federal OSHA severe-injury report for A.J. Stoves & Pellets, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5773 COLORADO STREET
City
MARION
State
PA
ZIP
17235
Mailing
P.O. BOX 152, SOUTH MOUNTAIN, PA 17261
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
SIC code (legacy)
2499
Employees
2
Ownership type
Private (A)

1 citation on file for this inspection.

1910.22 A01

Other-than-serious Gravity 05 1 instance 1 exposed
Issued
Oct 27, 2010
Abate by
Jun 30, 2011
Penalty
Initial $750 · Current $750

Hazardous substances W103

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to the potential hazard of fire and explosion:
(a)Storage Bin, Dust Collector and Cyclone - An employee operated stove
pellet
making machinery.  The employer did not insure that the 2 cyclone, storage
bin
and dust collector were provided with deflagration venting, on or about
August
5, 2010.
Abatement Note:
Among other methods, one feasible and acceptable abatement method to
correct theses
hazards is contained in the National Fire Protection Association (NFPA)
664, "Standard
for the Prevention of Fires and Explosions in Wood Processing and
Woodworking
Facilities" (2007 Edition)
*Section 8.2.2.5.3 Dust Collectors with Deflagration Hazards.  Dust
collectors with a deflagration hazard shall be designed and constructed in
accordance with one of the following 8.2.2.5.3(1) through 8.2.2.5.3(4).
*Section 8.4.2.4  Size reduction equipment shall be located outdoors.
Exception: Size reduction equipment shall be permitted indoors if located
in a detached building or separated from other production areas by
damage-limiting construction.
*Section 8.4.2.4.2 Size Reduction Equipment with a Deflagration Hazard.
Size reduction equipment shall be construction in accordance with one of
the following 8.4.2.4.2(1) through 8.4.2.4.2(3).
*Section 8.10.3.2  Silos and Storage Bins.  Silos and storage bins with a
deflagration hazard shall be equipped with either of the following in
8.10.3.2(1) or 8.10.3.2(2).
VERIFICATION REQUIREDTION
Recent events (2)
  • · I (O) $750.00
  • · Z (S) $750.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 312508047.