KISSIMMEE, FL —
OSHA Inspection: CELTIC ADVANCE CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CELTIC ADVANCE CONSTRUCTION, INC. in 22 N DILLINGHAM AVE, KISSIMMEE, FL 34741 (NAICS 238130). OSHA activity number 312516529.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CELTIC ADVANCE CONSTRUCTION, INC.
- Site address
- 22 N DILLINGHAM AVE
- City
- KISSIMMEE
- State
- FL
- ZIP
- 34741
- Mailing
- P O BOX 938434, MARGATE, FL 33063
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 9
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 20, 2008
- Abate by
- Aug 26, 2008
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being crushed by collapsing wooden trusses: a. At the site known as Dillingham Professional Office, the metal plate connected wood roof trusses were installed without bracing as required by BCSI 1-03 Guide to Good Practice for Handling, Installing and Bracing of Metal Plate Connected Wood Trusses. 25 trusses were installed using wooden spacers and had inadequate lateral and diagonal bracing. One feasible and acceptable abatement method to correct these hazards is to install roof trusses in accordance the recommendations of the Wood Truss Council of America and the Truss Plate Institute's recommendations which are contained in BCSI 1-03, Guide to Good Practice for Handling, Installing and Bracing Metal Plate Connected Wood Trusses. The truss manufacturer provides a copy of the BCSI 1-03 with the delivery of the trusses. Assure that during truss installation the ends are secured using adequate number of nails and that the trusses are braced as required with lateral, diagonal and horizontal bracing.
1926.102 A01
- Issued
- Aug 20, 2008
- Abate by
- Aug 25, 2008
- Penalty
- Initial $750 · Current $750
1926.501 B01
- Issued
- Aug 20, 2008
- Abate by
- Aug 25, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.501 B15
- Issued
- Aug 20, 2008
- Abate by
- Aug 25, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.503 A01
- Issued
- Aug 20, 2008
- Abate by
- Sep 2, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.1053 B13
- Issued
- Aug 20, 2008
- Abate by
- Aug 25, 2008
- Penalty
- Initial $1,500 · Current $1,500
1926.20 B01
- Issued
- Aug 20, 2008
- Abate by
- Sep 22, 2008
1926.405 G02 IV
- Issued
- Aug 20, 2008
- Abate by
- Aug 25, 2008
More inspections at Celtic Advance Construction, INC.
View Celtic Advance Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312516529.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.