ROBINS AFB, GA —
OSHA Inspection: CUSTOM STRUCTURES & REPAIR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CUSTOM STRUCTURES & REPAIR in EAGLE STREET, ROBINS AFB, GA 31098 (NAICS 238120). OSHA activity number 312522022.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM STRUCTURES & REPAIR
- Site address
- EAGLE STREET
- City
- ROBINS AFB
- State
- GA
- ZIP
- 31098
- Mailing
- 100 BREWTON COLLINS RD, CLAXTON, GA 30417
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- SIC code (legacy)
- 1791
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 17, 2008
- Abate by
- Oct 27, 2008
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards, while operating a scissors lift at a construction site. On or about 09/05/08 at Robins Air Force Base, GA: An employee was exposed to fall hazards, while operating a scissors lift at a construction site. The employer failed to ensure that a scissors lift was operated on an adequate surface. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: The employer should ensure that scissors lifts are placed on adequate surfaces required to support and withstand the load forces imposed during all operating conditions. The correct type of scissors lift should be selected based on the job tasks and conditions. A rough terrain type scissors lift should be used for construction work, which is performed on surfaces found on the exterior of a buildings at construction sites. Employees should be trained on the operation of the scissors lift in accordance with ANSI Standard A92.6-1990 and the manufacturer's operators manual. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
1926.20 B01
- Issued
- Oct 17, 2008
- Abate by
- Nov 13, 2008
- Penalty
- Initial $750 · Current $750
1926.761 B
- Issued
- Oct 17, 2008
- Abate by
- Nov 13, 2008
- Penalty
- Initial $750 · Current $750
More inspections in this industry (NAICS 238120)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312522022.