OSHA Inspection: ALL-LIFT SYSTEMS INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ALL-LIFT SYSTEMS INC in 333 WEST 29TH AVE, OSHKOSH, WI 54902 (NAICS 332618). OSHA activity number 312559131.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch All-Lift Systems INC — free Get an email when a new federal OSHA severe-injury report for All-Lift Systems INC is published. One employer, no account, unsubscribe in one click.
Site address
333 WEST 29TH AVE
City
OSHKOSH
State
WI
ZIP
54902
Mailing
2146 WEST PERSHING ST, APPLETON, WI 54914
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
SIC code (legacy)
3496
Employees
2
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 1 exposed
Issued
Dec 15, 2010
Abate by
Dec 20, 2010
Penalty
Initial $2,677 · Current $1,350 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to fall hazards from a scissor lift platform:
a)On November 22, 2010 a scissors lift (JLG 1930ES) was being used with
the platform
being elevated to approximately 15' above the cement floor without the mid
rail chain
attached on the access opening to the platform, exposing the operator to a
fall from the
lift.
Among other methods, feasible and acceptable means to correct the hazard
are to ensure
the scissor lift is operated according to the Operator's manual and
appropriate sections
of theAmerican National Standards for Self-propelled Elevating Work
Platforms (ANSI
A92.6-2006). Section 7.10.4 states that guardrails shall be installed and
positioned, and
access gates or openings shall be closed per the manufacturer's
instructions. Section
8.8.2 states that prior to each elevation the operator shall ensure
guardrails are installed
and access gates or openings are closed per the manufacturer's
instructions.
No Abatement Certification or Abatement Documentation required.tion
Recent events (2)
  • — I (S) $1350.00
  • — Z (S) $2677.00