Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCGEAN-ROHCO INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCGEAN-ROHCO INC. in 2910 HARVARD AVE., NEWBURGH HTS, OH 44105 (NAICS 325998). OSHA activity number 312564008.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcgean-Rohco INC. — free Get an email when a new federal OSHA severe-injury report for Mcgean-Rohco INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MCGEAN-ROHCO INC.
Site address
2910 HARVARD AVE.
City
NEWBURGH HTS
State
OH
ZIP
44105
Mailing
2910 HARVARD AVE., NEWBURGH HEIGHTS, OH 44105
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
SIC code (legacy)
2819
Employees
55
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 03 4 instances 30 exposed
Issued
Feb 17, 2009
Abate by
Mar 22, 2009
Penalty
Initial $875
5(a)(1): Section 5 (a)(1) of the Occupational Safety and Health Act of
1970:  The employer did not furnish
employment and a place of employment which were free from recognized
hazards that were causing or likely
to cause death or serious physical harm, including severe burns,  to
employees in that employees were
exposed to the hazard of  dust explosions, deflagration or other hazards
from Chrome processing equipment:
a)Processing area was not separated from other parts of the building due
to openings in fire walls which
did not have an approved self-closing fire door.
b)Access doors were not bonded and grounded.
c)A cyclone is not protected with explosion protection systems and is
located inside the building.
d)No devices to limit or prevent explosions in the spray dryer were
provided.
Among other methods, a feasible abatement method to correct this hazard is:
Remove hold open devices on door and repair the latching device and
install doors in other fire wall
penetrations.  Install bonding and grounding wires on all access doors in
equipment.  Relocate cyclone outside
the building and install relief venting or other explosion suppression or
prevention system.  Install devices to
prevent or limit the effects of explosions in the spray dryer.
Installations and modifications  should be done
per requirements of the National Fire Protection Association (NFPA) 654
Standard for the Prevention of Fire
and Dust Explosions from the Manufacturing, Processing and Handling of
Combustible Solids and NFPA 69
Standard on Explosion Prevention Systems and NFPA 68 Guide for Venting
Deflagrations.
Recent events (2)
  • — I (S)
  • — Z (S) $875.00

View Mcgean-Rohco INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312564008.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.