NANTY GLO, PA ·
OSHA Inspection: ENVIRONMENTAL COORDINATION SERVICES & RECYCLING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ENVIRONMENTAL COORDINATION SERVICES & RECYCLING in 115 PACE STREET, NANTY GLO, PA 15943 (NAICS 562211). OSHA activity number 312629223.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENVIRONMENTAL COORDINATION SERVICES & RECYCLING
- Site address
- 115 PACE STREET
- City
- NANTY GLO
- State
- PA
- ZIP
- 15943
- Mailing
- 3237 US HIGHWAY 19, COCHRANTON, PA 16314
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562211
- SIC code (legacy)
- 4953
- Employees
- 22
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jan 21, 2009
- Abate by
- Jan 29, 2009
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion/fire hazards: (a)Jobsite, 115 Pace Street, Nanty Glo, PA: On or about 12/3/08 an employee was burned when a fire occurred during the vacuuming of flammables from an underground tank. The employee was using a 4" flexible pvc hose that was not bonded between the vacuum truck and tank. Among other methods, one feasible and acceptable abatement method to correct this hazard is to use a hose during the vacuuming of flammables that is constructed of conductive material or thick walled with imbedded conductive wiring so that there can be bonding between the vacuum truck and tank in accordance with the American Petroleum Institute (API) "Safe Operation of Vacuum Trucks in Petroleum Service", Sections 5.3.1, 5.3.2 and 5.4.1.1.