DELMONT, PA ·
OSHA Inspection: QUADRANT EPP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUADRANT EPP in 201 INDUSTRIAL DRIVE, DELMONT, PA 15626 (NAICS 326199). OSHA activity number 312632193.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUADRANT EPP
- Site address
- 201 INDUSTRIAL DRIVE
- City
- DELMONT
- State
- PA
- ZIP
- 15626
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- SIC code (legacy)
- 3089
- Employees
- 92
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 1, 2009
- Abate by
- Jun 5, 2009
- Penalty
- Initial $875 · Current $620 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to improperly maintained single girder underhung hoists: (a) Facility: On or about March 23, 2009, the following deficiencies were identified on the following single girder underhung hoists: *Press Area, Acco Wright, 2 ton, serial #532-07-6942, sheave groves were not smooth. *Press Area, Acco Wright, 2 ton, serial #532-07-5981, bridge brake is damaged and needs to be replaced. *Furnace Area, Acco Wright, 2 ton, serial # 532-07-5980, need shock absorbing bumpers on the trolley and replace the broken bridge guide rollers. *Fab Area, C & M, 1 ton, serial #LW-2956MS, the existing upper limit switch does not work. *Fab Area, C & M, 1 ton, serial #LW-554ORM, the existing upper limit switch does not work. Among other methods, one feasible and acceptable means of abatement would be to correct these items with either in house maintenance employees or correct them by bringing in an outside contractor.
Recent events (2)
- · I (S) $620.00
- · Z (S) $875.00
1910.179 L03 I
- Issued
- Apr 1, 2009
- Abate by
- Apr 20, 2009
- Penalty
- Initial $875 · Current $620 Reduced
Recent events (2)
- · I (S) $620.00
- · Z (S) $875.00
1910.212 A03 II
- Issued
- Apr 1, 2009
- Abate by
- Jun 5, 2009
- Penalty
- Initial $875 · Current $620 Reduced
Recent events (2)
- · I (S) $620.00
- · Z (S) $875.00
1910.215 B09
- Issued
- Apr 1, 2009
- Abate by
- Apr 9, 2009
- Penalty
- Initial $525 · Current $365 Reduced
Recent events (2)
- · I (S) $365.00
- · Z (S) $525.00
1910.303 G01
- Issued
- Apr 1, 2009
- Abate by
- Apr 9, 2009
More inspections in this industry (NAICS 326199)