Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: C W OHIO INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C W OHIO INC. in 1209 MAPLE AVENUE, CONNEAUT, OH 44030 (NAICS 325211). OSHA activity number 312673536.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C W Ohio INC. for free Get an email when a new federal OSHA severe-injury report for C W Ohio INC. is published. One employer, no account, unsubscribe in one click.
Establishment
C W OHIO INC.
Site address
1209 MAPLE AVENUE
City
CONNEAUT
State
OH
ZIP
44030
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
SIC code (legacy)
2821
Employees
220
Ownership type
Private (A)

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 4 exposed
Issued
Jan 29, 2009
Abate by
Nov 4, 2009
Penalty
Initial $1,375 · Current $700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to severe burns from potential dust explosion,deflagration
and fire hazards caused
by the improper design of the dust collection system.
a.The dust collector located outside the building did not have
deflagration venting.
b.The dust collector located inside the building did not have deflagration
venting or a fire
suppression system.
c.None of the ducts were grounded.
d.The ducts did not have explosion-isolation devices.
Among other methods, feasible and acceptable abatement method to correct
these
hazards
include the following:
*Have a qualified engineer inspect the dust collection system to ensure
that it is designed
and installed in accordance with National Fire Protection Association
(NFPA) 654-2006,
Standard for Prevention of Fire and Dust Explosions from the
Manufacturing,Processing
and Handling of Combustible Particulate Solids.
*Retrofit the dust collector located outside with deflagration venting, or
a fire suppression
system.
*Move the dust collector located inside the building to the outside of the
building, and
provide deflagration venting, or a fire suppression system.
*Bond and ground the dust collection system according to the NFPA Code.
*Design, construct, and install ducts with metal sufficient to withstand
the maximum
unvented deflagration pressure, an explosion suppression system, or
deflagration relief
venting.  Provide explosion-isolation devices on areas where ducts are
connected to
equipment.
Recent events (2)
  • · F (S) $700.00
  • · Z (S) $1375.00

1910.212 A01

Serious Gravity 03 1 instance 2 exposed
Issued
Jan 29, 2009
Abate by
Oct 21, 2009
Penalty
Initial $1,375 · Current $675 Reduced
Recent events (2)
  • · F (S) $675.00
  • · Z (S) $1375.00

1910.212 A01

Serious Gravity 02 1 instance 1 exposed
Issued
Jan 29, 2009
Abate by
Feb 3, 2009
Recent events (2)
  • · F (S)
  • · Z (S)

1910.134 C02 I

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Jan 29, 2009
Abate by
Feb 3, 2009
Recent events (2)
  • · F (O)
  • · Z (O)

View C W Ohio INC.'s full OSHA safety record →