OSHA Inspection: HINSON ELECTRIC INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HINSON ELECTRIC INC in 2346 PLEASANT RD, FORT MILL, SC 29708 (NAICS 238210). OSHA activity number 312822083.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hinson Electric INC — free Get an email when a new federal OSHA severe-injury report for Hinson Electric INC is published. One employer, no account, unsubscribe in one click.
Establishment
HINSON ELECTRIC INC
Site address
2346 PLEASANT RD
City
FORT MILL
State
SC
ZIP
29708
Mailing
2200 STAFFORD ST, MONROE, NC 28112
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
17
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

10012 A

Serious Gravity 03 1 instance 5 exposed
Issued
Feb 11, 2009
Abate by
Feb 17, 2009
Penalty
Initial $500 · Current $200 Reduced
SCRR 71-112A: Failed to furnish a place of employment which is free of
recognized hazards
which may cause death or serious physical harm to his employees and comply
with this
regulation and other occupational safety and health rules and regulations
promulgated under
Chapter 15 of Title 41, Code of Laws, State of South Carolina, 1976, as
amended, as
follows:
A.  Employer knew or should have known that operating a Bobcat forklift,
Model S175, with
inoperable reverse signal alarm and no observer used constituted a hazard
of employees being
struck by forklift when operated in reverse gear at the Fort Mill
Elementary School Number
7 job site.  A feasible and useful method, among others, to correct this
hazard is to repair
the reverse signal alarm.
Recent events (2)
  • — I (S) $200.00
  • — Z (S) $500.00

View Hinson Electric INC's full OSHA safety record →