CLIFTON, NJ —
OSHA Inspection: MTS FRAMES, INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MTS FRAMES, INC in 65 WALMAN AVE., CLIFTON, NJ 07011 (NAICS 321999). OSHA activity number 312859648.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MTS FRAMES, INC
- Site address
- 65 WALMAN AVE.
- City
- CLIFTON
- State
- NJ
- ZIP
- 07011
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- SIC code (legacy)
- 2499
- Employees
- 15
- Ownership type
- A
Citations
19 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 24, 2009
- Abate by
- Feb 28, 2010
- Penalty
- Initial $1,500 · Current $600 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)Second Level, Pistorius (Torit) Dust Collector Model P19-FB: The collector which recycles exaust air was not provided with a listed spark detection and extinguishing system, on or about June 25, 2009. b)Second Level, Pistorius (Torit) Dust Collector Model P20-3FB55: The collector which recycles exaust air was not provided with a listed spark detection and extinguishing system, on or about June 25, 2009. c)Second Level, Pistorius (Torit) Dust Collectors listed above were located in the same room but were not separated by at least 20 feet, on or about June 25, 2009. d)Second Level, Pistorius (Torit) Dust Collectors listed above were cleaned with compressed air although electrical power was not shut down, on or about June 25, 2009. e)Second Level, Pistorius (Torit) Dust Collectors: The collected dust collector was removed on a daily basis, on or about June 25, 2009. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct to correct the hazard is to comply with the National Fire Protection Association (NFPA 664) "Standards for the Prevention of Fires and Explosion in Wood Processing and Woodworking Facilities."
Recent events (2)
- — I (S) $600.00
- — Z (S) $1500.00
1910.106 E02 IVB
- Issued
- Nov 24, 2009
- Abate by
- Nov 30, 2009
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.106 E02 IIB2
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.106 E02 IVA
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.107 B09
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.107 G02
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.176 C
- Issued
- Nov 19, 2009
- Abate by
- Dec 30, 2009
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.213 H01
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.303 B02
- Issued
- Nov 19, 2009
- Abate by
- Dec 30, 2009
- Penalty
- Initial $450 · Current $180 Reduced
Recent events (2)
- — I (S) $180.00
- — Z (S) $450.00
1910.1200 E01
- Issued
- Nov 19, 2009
- Abate by
- Jan 30, 2010
- Penalty
- Initial $1,500 · Current $600 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1500.00
1910.1200 F05 I
- Issued
- Nov 19, 2009
- Abate by
- Jan 30, 2010
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 F05 II
- Issued
- Nov 19, 2009
- Abate by
- Jan 30, 2010
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H03 II
- Issued
- Nov 19, 2009
- Abate by
- Jan 30, 2010
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H03 III
- Issued
- Nov 19, 2009
- Abate by
- Mar 30, 2010
Recent events (2)
- — I (S)
- — Z (S)
1910.134 C01
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
1910.134 E01
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
1910.134 F01
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
1910.134 K01 I
- Issued
- Nov 19, 2009
- Abate by
- Jan 15, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.141 D02 III
- Issued
- Nov 19, 2009
- Abate by
- Nov 24, 2009
More inspections at MTS Frames, INC
View MTS Frames, INC's full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312859648.