DURHAM, NC ·
OSHA Inspection: ARCENIO NAVA ALBARRAN DBA ARCENIO NAVA ALBARRAN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARCENIO NAVA ALBARRAN DBA ARCENIO NAVA ALBARRAN in 106 PATHWOOD LANE, DURHAM, NC 27705 (NAICS 238170). OSHA activity number 312872260.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCENIO NAVA ALBARRAN DBA ARCENIO NAVA ALBARRAN
- Site address
- 106 PATHWOOD LANE
- City
- DURHAM
- State
- NC
- ZIP
- 27705
- Mailing
- 110 YORK STREET, CARY, NC 27511
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- SIC code (legacy)
- 1761
- Employees
- 3
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
8 citations on file for this inspection.
95012901
- Issued
- Jan 27, 2009
- Abate by
- Jan 30, 2009
- Penalty
- Initial $175 · Current $175
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards: a)job site - where employee(s) installing siding operated a Hitachi pneumatic nail gun (NT65M2, maximum air pressure 100 PSI) with the air pressure set at 124 PSI. Abatement note: One feasible and acceptable abatement method, among others, to correct this hazard is limit air pressure to the rated pressure of the Hitachi pneumatic nail gun (100 PSI). Reference: ANSI/ISANTA SNT-101-1983; American National Standard for power tools - heavy-duty, portable, compressed-air-actuated, fastener driving tools- safety requirements for, Section 10: Tool Installation Instructions. Hitachi pneumatic nail gun instructions manual.tions
1926.102 A01
- Issued
- Jan 27, 2009
- Abate by
- Jan 30, 2009
- Penalty
- Initial $175 · Current $175
1926.501 B13
- Issued
- Jan 27, 2009
- Abate by
- Jan 30, 2009
- Penalty
- Initial $125 · Current $125
1926.20 B02
- Issued
- Jan 27, 2009
- Abate by
- Feb 23, 2009
1926.1053 B04
- Issued
- Jan 27, 2009
- Abate by
- Jan 30, 2009
- Penalty
- Initial $125 · Current $125
1926.404 F07 IVC
- Issued
- Jan 27, 2009
- Abate by
- Jan 30, 2009
1926.405 A02 III
- Issued
- Jan 27, 2009
- Abate by
- Jan 30, 2009
1926.503 B01
- Issued
- Jan 27, 2009
- Abate by
- Feb 23, 2009