HENDERSON, NV —
OSHA Inspection: GERALD NASH ELECTRIC, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GERALD NASH ELECTRIC, INC. in 1471 PASEO VERDE PARKWAY, HENDERSON, NV 89012 (NAICS 238210). OSHA activity number 312899982.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GERALD NASH ELECTRIC, INC.
- Site address
- 1471 PASEO VERDE PARKWAY
- City
- HENDERSON
- State
- NV
- ZIP
- 89012
- Mailing
- 8303 EVERGREEN DRIVE, HELENA, MT 59602
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- SIC code (legacy)
- 1731
- Employees
- 4
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
618037501
- Issued
- Apr 1, 2009
- Abate by
- Apr 3, 2009
- Penalty
- Initial $375 · Current $375
General-duty citation text
Nevada Revised Statute 618.375(1): Every employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or were likely to cause death or serious physical harm to his employees: The employer did not protect employees as follows: a.At the Marriott, on the south side of the building, an employee used an unapproved scaffold platform attached to a rough terrain forklift to lift employees and materials, exposing the employees to fall hazards of approximately 28 feet if the scaffold or forklift were to fail. It was not necessary for the rough terrain forklift to be used to lift the employees. The platform was open on the front side, lacking railings, and the employees did not use any type of restraining means such as a harness and lanyard. Also an employee entered the platform from the scaffold instead of at floor level. Reference ANSI/ITSDF B56.6-2005 part II for the user: Paragraph 5.15.1 - a rough terrain forklift shall not be used to lift people unless there is no other practical option. Paragraph 5.15.1(k) - be certain that required straining means such as railings, chains, cable, body belt(s) with lanyards(s), etc., are in place and properly used. Paragraph 5.15.1(w) - platform shall be lowered to floor level for personnel to enter and exit. One feasible means of abatement would be to follow the requirements of ANSI/ITSDF B56.6- 20056-
More inspections at Gerald Nash Electric, INC.
View Gerald Nash Electric, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312899982.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.