OSHA Inspection: VEOLIA ENVIRONMENTAL SERVICES

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of VEOLIA ENVIRONMENTAL SERVICES in FM 2917, ALVIN, TX 77512 (NAICS 562910). OSHA activity number 312927858.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veolia Environmental Services — free Get an email when a new federal OSHA severe-injury report for Veolia Environmental Services is published. One employer, no account, unsubscribe in one click.
Site address
FM 2917
City
ALVIN
State
TX
ZIP
77512
Mailing
2000 N. HIGHWAY 146, LA PORTE, TX 77571
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
SIC code (legacy)
1799
Employees
3
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Sep 15, 2011
Abate by
Sep 19, 2011
Penalty
Initial $6,300
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to:
The hazards of thermal burns from water with temperatures of approximately
170
degrees farenheit while working near and around the ECU boiler Blow-Down
condensate
sump.  An Employee on May 05, 2011, was attempting to fill two five-gallon
buckets
with water from the condensate pit.  The worker fell into the pit and
sustained fatal
thermal burns.  There were no signs placed to alert employees of the
hazards of
dangerous hot water temperatures.
One feasible and acceptable method, among others, to correct this hazard
would be to
comply with American National Standards Institute (ANSI) Z35.1-1972,
Specifications
for
Accident Prevention Signs, page 10, paragraph 7.1 which states, "Signs
shall be posted
to alert and inform in sufficient time to avoid the hazard or take
appropriate action."
Recent events (2)
  • — J (S)
  • — Z (S) $6300.00

1910.305 B01 II

Deleted Serious Gravity 01 4 instances 3 exposed
Issued
Sep 15, 2011
Abate by
Sep 19, 2011
Penalty
Initial $2,295
Recent events (2)
  • — J (S)
  • — Z (S) $2295.00

View Veolia Environmental Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312927858.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.