OSHA Inspection: CANDLEWIC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CANDLEWIC in 3765 OLD EASTON ROAD, DOYLESTOWN, PA 18901 (NAICS 339999). OSHA activity number 312976145.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Candlewic — free Get an email when a new federal OSHA severe-injury report for Candlewic is published. One employer, no account, unsubscribe in one click.
Establishment
CANDLEWIC
Site address
3765 OLD EASTON ROAD
City
DOYLESTOWN
State
PA
ZIP
18901
Mailing
3765 OLD EASTON ROAD, DOYLESTOWN, PA 18901
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339999
SIC code (legacy)
3999
Employees
19
Ownership type
A

16 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 1, 2009
Penalty
Initial $1,500 · Current $750 Reduced
Section 5(a)1 of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free of recognized hazards
that were causing
or likely to cause death or serious physical harm to employees in that
employees were exposed
to fall hazards while using improperly maintained mobile ladder stands.
a) Candlewic, Warehouse - On or about August 11, 2009, a 10 riser mobile
ladder stand
is in use by employees that has damaged parts and is covered in paraffin
wax on all
treadles creating multiple fall hazards from no less than 7'10" above
grade.
ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement
method
to correct this hazard is: Comply with the manufacturer's requirements and
ANSI A14.7-1991
for Mobile Ladder Stands and Mobile Ladder Stand Platforms. Section 6.3
requires: "Units that
are damaged subsequent to their receipt, and/or are worn beyond repair
shall be destroyed.
Never climb a damaged ladder stand or ladder." Section 7.2.3 reads, "The
owner of a unit, or
employer having supervisory control of a unit, has the total
responsibility for its proper
inspection, setup, use, and maintenance."
No abatement certification or documentation required.tion
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

5(a)(1)

Serious Gravity 03 5 instances 2 exposed
Issued
Sep 28, 2009
Abate by
Oct 1, 2009
Penalty
Initial $750 · Current $375 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to crushing injuries due to improperly assembled storage
racking systems:
a) Candlewic, Warehouse - On or about August 11, 2009, no less than five
front cross
bars of a steel storage shelving system were not fully secured. Only one
of the teardrop
stud and keyhole slot connections was partially engaged, exposing
employees to the
hazard of being crushed by unsecured rack components and stored materials
while
working in the vicinity of the overhead storage.
ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement
is to
ensure the structural integrity of the storage racks is maintained through
a program of routine
inspections to identify those conditions that require repair and/or
replacement of missing or
damaged parts in accordance with ANSI MH16.1 - 2004, Specification for the
Design, Testing
and Utilization of Industrial Steel Storage Racks, section 1.4 Integrity
of Rack Installations.
No abatement certification or documentation required.tion
Recent events (2)
  • — I (S) $375.00
  • — Z (S) $750.00

1910.23 E01

Serious Gravity 02 1 instance 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 1, 2009
Penalty
Initial $600 · Current $300 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $600.00

1910.37 A03

Serious Gravity 02 2 instances 7 exposed
Issued
Sep 28, 2009
Abate by
Oct 1, 2009
Penalty
Initial $600 · Current $300 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $600.00

1910.101 B

Serious Gravity 02 1 instance 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 1, 2009
Penalty
Initial $600 · Current $300 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $600.00

1910.147 C01

Serious Gravity 03 1 instance 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 23, 2009
Penalty
Initial $750 · Current $375 Reduced
Recent events (2)
  • — I (S) $375.00
  • — Z (S) $750.00

1910.151 C

Serious Gravity 03 1 instance 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 30, 2009
Penalty
Initial $750 · Current $375 Reduced
Recent events (2)
  • — I (S) $375.00
  • — Z (S) $750.00

1910.157 G03

Serious Gravity 03 7 instances 7 exposed
Issued
Sep 28, 2009
Abate by
Oct 23, 2009
Penalty
Initial $750 · Current $375 Reduced
Recent events (2)
  • — I (S) $375.00
  • — Z (S) $750.00

1910.178 L

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 23, 2009
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

1910.212 A01

Serious Gravity 10 3 instances 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 1, 2009
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

1910.305 G01 III

Serious Gravity 03 1 instance 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 1, 2009
Penalty
Initial $750 · Current $375 Reduced
Recent events (2)
  • — I (S) $375.00
  • — Z (S) $750.00

1910.1200 E01

Serious Gravity 10 1 instance 7 exposed
Issued
Sep 28, 2009
Abate by
Oct 23, 2009
Penalty
Initial $1,500 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

1910.1200 H

Serious Gravity 10 1 instance 7 exposed
Issued
Sep 28, 2009
Abate by
Oct 23, 2009

1904.29 A

Other-than-serious Gravity 00 2 instances 7 exposed
Issued
Sep 28, 2009
Abate by
Sep 28, 2009

1910.303 G01 I

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Sep 28, 2009
Abate by
Oct 1, 2009

1910.303 B02

Other-than-serious Gravity 01 1 instance 5 exposed
Issued
Sep 28, 2009
Abate by
Sep 28, 2009

View Candlewic's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 312976145.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.