Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J.F. ELECTRIC, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of J.F. ELECTRIC, INC. in IL ROUTE 158 AND QUARRY ROAD, MILLSTADT, IL 62260 (NAICS 238210). OSHA activity number 313012114.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.F. Electric, INC. — free Get an email when a new federal OSHA severe-injury report for J.F. Electric, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
J.F. ELECTRIC, INC.
Site address
IL ROUTE 158 AND QUARRY ROAD
City
MILLSTADT
State
IL
ZIP
62260
Mailing
BOX 570 ROUTE 143, EDWARDSVILLE, IL 62025
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
SIC code (legacy)
1731
Employees
5
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Sep 14, 2009
Abate by
Sep 18, 2009
Penalty
Initial $5,000 · Current $2,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that the
company did not follow manufacturer's recommendations regarding the
maintenance of a
Lift-All aerial device:
On and about May 20, 2009, employees using a Lift-All Aerial Device, Model
Number
LAN-65-2E, Serial Number 5896039865LAN, were exposed to fall hazards
resulting from
chain failure and the company did not adhere to the critical inspections
and tests outlines in
the maintenance & repair parts manual from Lift-All Hoist in that the
chains were not
removed and cleaned for inspection to identify cracks.
American National Standard for Vehicle-Mounted Elevating and Rotating
Aerial Devices, ANSI/SIA A92.2 2001, paragraph 8.2.4, states:
"Periodic Inspection and Test:  An inspection of the mobile units shall be
performed at the intervals defined in 8.2.2 depending upon its activity,
severity
of service, and environment, or as specifically indicated below (These
inspections shall include the requirements of 8.2.3).
(1)  Structural members for deformation, cracks or corrosion."
Among other methods, one feasible and acceptable method to abate this
hazard is for the
employer to remove, clean, and inspect the chain per the manufacturer's
requirement.
ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE
WITH THE REQUIREMENTS OF 29 CFR 1903.19(d).S
Recent events (2)
  • — F (O) $2500.00
  • — Z (S) $5000.00

View J.F. Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313012114.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.