MILLSTADT, IL —
OSHA Inspection: J.F. ELECTRIC, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of J.F. ELECTRIC, INC. in IL ROUTE 158 AND QUARRY ROAD, MILLSTADT, IL 62260 (NAICS 238210). OSHA activity number 313012114.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.F. ELECTRIC, INC.
- Site address
- IL ROUTE 158 AND QUARRY ROAD
- City
- MILLSTADT
- State
- IL
- ZIP
- 62260
- Mailing
- BOX 570 ROUTE 143, EDWARDSVILLE, IL 62025
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- SIC code (legacy)
- 1731
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Sep 14, 2009
- Abate by
- Sep 18, 2009
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the company did not follow manufacturer's recommendations regarding the maintenance of a Lift-All aerial device: On and about May 20, 2009, employees using a Lift-All Aerial Device, Model Number LAN-65-2E, Serial Number 5896039865LAN, were exposed to fall hazards resulting from chain failure and the company did not adhere to the critical inspections and tests outlines in the maintenance & repair parts manual from Lift-All Hoist in that the chains were not removed and cleaned for inspection to identify cracks. American National Standard for Vehicle-Mounted Elevating and Rotating Aerial Devices, ANSI/SIA A92.2 2001, paragraph 8.2.4, states: "Periodic Inspection and Test: An inspection of the mobile units shall be performed at the intervals defined in 8.2.2 depending upon its activity, severity of service, and environment, or as specifically indicated below (These inspections shall include the requirements of 8.2.3). (1) Structural members for deformation, cracks or corrosion." Among other methods, one feasible and acceptable method to abate this hazard is for the employer to remove, clean, and inspect the chain per the manufacturer's requirement. ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH THE REQUIREMENTS OF 29 CFR 1903.19(d).S
Recent events (2)
- — F (O) $2500.00
- — Z (S) $5000.00
More inspections at J.F. Electric, INC.
View J.F. Electric, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313012114.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.