Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: LUSTIG CUSTOM CABINETS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUSTIG CUSTOM CABINETS, LLC in 921 E. FAYETTE AVENUE, EFFINGHAM, IL 62041 (NAICS 337110). OSHA activity number 313014391.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lustig Custom Cabinets, LLC for free Get an email when a new federal OSHA severe-injury report for Lustig Custom Cabinets, LLC is published. One employer, no account, unsubscribe in one click.
Site address
921 E. FAYETTE AVENUE
City
EFFINGHAM
State
IL
ZIP
62041
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
SIC code (legacy)
2434
Employees
11
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 4 exposed
Issued
Mar 29, 2010
Abate by
May 13, 2010
Penalty
Initial $300 · Current $210 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to flying plastic projectile hazards due to possible
mechanical failure of the plastic
polyvinyl chloride (PVC) piping system used in during cabinet production:
Employees were exposed to the hazards of flying shrapnel from an exploding
plastic PVC
pipe, 3/4 inch Schedule 40 PVC pipe to transport compressed throughout the
Case Work
Area or eastern room of the manufacturing facility.  The piping ran from
the air
compressor up to the  ceiling and along the room.  The compressed air was
at an
operating pressure of 120 pounds per square inch (PSI).
Among other methods, the following are feasible and acceptable methods to
correct this
hazard:
1.Replace the current PVC compressed air piping system with materials
suitable for the maximum air pressure as recommended by the Plastic Pipe
Institute, such as ABS or metal.
2.Follow the American National Standards Institute/American Society of
Mechanical Engineers (ANSI/ASME) B31.1-2007, Power Piping, as
applicable.
Abatement certification is required for this item in accordance with the
requirements of 29 CFR
1903.19(c).
Recent events (2)
  • · I (S) $210.00
  • · Z (S) $300.00

1910.304 A02

Serious Gravity 02 4 instances 4 exposed
Issued
Mar 29, 2010
Abate by
Apr 22, 2010
Penalty
Initial $300 · Current $210 Reduced
Recent events (2)
  • · I (S) $210.00
  • · Z (S) $300.00

1910.304 F04

Serious Gravity 02 1 instance 2 exposed
Issued
Mar 29, 2010
Abate by
Apr 22, 2010
Penalty
Initial $300 · Current $210 Reduced