OSHA Inspection: MAGNESIUM ELEKTRON NORTH AMERICA INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAGNESIUM ELEKTRON NORTH AMERICA INC. in 1001 COLLEGE STREET, MADISON, IL 62060 (NAICS 331492). OSHA activity number 313017204.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Magnesium Elektron North America INC. — free Get an email when a new federal OSHA severe-injury report for Magnesium Elektron North America INC. is published. One employer, no account, unsubscribe in one click.
Site address
1001 COLLEGE STREET
City
MADISON
State
IL
ZIP
62060
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331492
SIC code (legacy)
3341
Employees
85
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 05 1 instance 20 exposed
Issued
Feb 14, 2011
Abate by
Feb 17, 2011
Penalty
Initial $3,825
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment that were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees, in that
employees were exposed to fire and explosion:
On or about Oct. 4, 2010 employees were exposed to fire and explosion
hazards due to the
close proximity of a sprinkler system riser to an oven that heated
magnesium metal.  The
heat from a magnesium fire in Oven 5B ruptured the sprinkler system riser
releasing water
onto molten metal causing a series of explosions.
Among other methods, one feasible and accepted abatement method to correct
this hazard is
to move the oven away from the sprinkler riser in accordance with NFPA
86-2011, National
Fire Protection Agency Standard for Ovens and Furnaces.
Recent events (2)
  • — I (S)
  • — Z (S) $3825.00

1910.303 B01

Serious Gravity 05 2 instances 5 exposed
Issued
Feb 14, 2011
Abate by
Mar 17, 2011
Penalty
Initial $3,825 · Current $3,825

1910.303 F02

Serious Gravity 05 1 instance 3 exposed
Issued
Feb 14, 2011
Abate by
Mar 10, 2011
Penalty
Initial $3,060 · Current $3,060

1910.303 G02 I

Serious Gravity 05 1 instance 3 exposed
Issued
Feb 14, 2011
Abate by
Mar 10, 2011

1910.305 B01 II

Serious Gravity 05 1 instance 3 exposed
Issued
Feb 14, 2011
Abate by
Mar 10, 2011

1910.305 G01 IVA

Serious Gravity 05 2 instances 6 exposed
Issued
Feb 14, 2011
Abate by
Mar 17, 2011
Penalty
Initial $3,060 · Current $3,060

View Magnesium Elektron North America INC.'s full OSHA safety record →