NASHVILLE, IL ·
OSHA Inspection: TRUCK REPAIR SERVICE CENTERS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TRUCK REPAIR SERVICE CENTERS, LLC in 17906 MOCKINGBIRD ROAD, NASHVILLE, IL 62236 (NAICS 811310). OSHA activity number 313017451.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRUCK REPAIR SERVICE CENTERS, LLC
- Site address
- 17906 MOCKINGBIRD ROAD
- City
- NASHVILLE
- State
- IL
- ZIP
- 62236
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- SIC code (legacy)
- 7699
- Employees
- 25
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 30, 2010
- Abate by
- Feb 15, 2011
- Penalty
- Initial $2,040 · Current $2,040
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Employees were exposed to the hazards of flying shrapnel from an exploding plastic PVC pipe, 1.5 inch Genova 1120 Schedule 40 PVC pipe to transport compressed throughout the shop area, from the south wall to all sections of the shop. The piping ran from the air compressor up to the ceiling and then to the east and west walls. The compressed air was at an operating pressure of 115 pounds per square inch (PSI). Among other methods, the following are feasible and acceptable methods to correction. 1. Replace the current PVC compressed air piping system with materials suitable for the maximum air pressure as recommended by the Plastic Pipe Institute, such as ABS or metal. 2. Follow the American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) B31.1-2007, Power Piping, as applicable. Abatement certification is required for this item in accordance with the requirement of 29 CFR 1903.19(c).
More inspections in this industry (NAICS 811310)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313017451.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.