CORPUS CHRISTI, TX —
OSHA Inspection: P.W.C. INDUSTRIES INC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of P.W.C. INDUSTRIES INC in 6650 LEOPARD ST, CORPUS CHRISTI, TX 78409 (NAICS 333132). OSHA activity number 313036402.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- P.W.C. INDUSTRIES INC
- Site address
- 6650 LEOPARD ST
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78409
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333132
- SIC code (legacy)
- 3533
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 23, 2009
- Abate by
- Oct 5, 2009
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing, or likely to cause, death or serious physical harm to employees in that employees were exposed to struck by hazards from unguarded pressure testing of fabricated piping sections: P.W.C. Industries, Inc., does not protect its employees from high pressure ruptures during hydrostatic testing of pipeline sections. Employees are exposed to struck-by hazards created by the use of a high pressure positive displacement pump and the associated work pieces being used to evaluate fabricated piping sections for leaks while under test pressure exceeding 2100 psig. This violation most recently occurred on or about March 24, 2009 at this fabrication yard operated at 6650 Leopard Street, Corpus Christi, TX 78409-1611. Employees were addressing leaks with hand tools and pneumatic tools in close proximity to the equipment without it's being pressured down and without barrier guard protection. Among other methods, one feasible and acceptable means of abatement to correct this hazard is to adopt the American Society of Mechanical Engineers (ASME) B31.8 (2007) code for pressure piping. Section 841.36 - "Safety During Tests" states in paragraph 841.36 - "All testing of pipelines and mains after construction shall be done with due regard for the safety of employees and the public during the test. Pursuant to 29 CFR 1903.19, the employer must submit documents describing the steps it is taking to ensure compliance, including an explanation of how these steps protect its employees from unexpected high pressure releases during hydrostatic testing of fabricated piping sections.
Recent events (2)
- — I (O) $1500.00
- — Z (S) $1500.00
1910.135 A01
- Issued
- Sep 23, 2009
- Abate by
- Sep 28, 2009
- Penalty
- Initial $375
Recent events (2)
- — I (S)
- — Z (S) $375.00
More inspections at P.W.C. Industries INC