GLENVIEW, IL ·
OSHA Inspection: PAINT IT THE TRUTH DECORATING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PAINT IT THE TRUTH DECORATING, INC. in 1862 JOHNS DRIVE, GLENVIEW, IL 60025 (NAICS 337110). OSHA activity number 313064917.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PAINT IT THE TRUTH DECORATING, INC.
- Site address
- 1862 JOHNS DRIVE
- City
- GLENVIEW
- State
- IL
- ZIP
- 60025
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- SIC code (legacy)
- 2434
- Employees
- 6
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 14, 2009
- Abate by
- Sep 28, 2009
- Penalty
- Initial $750 · Current $750
M102
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to serious burns from potential dust deflagration, explosion, or other fire hazards as the result of the improper design and maintenance of the dust collection systems: Paint it the Truth Decorating, Inc., Glenview, IL: The Grizzly Industrial, Inc. Model G0441 3 HP cyclone dust collector was not equipped or used with the following. (a) A means of tramp metal protection was not provided to keep any unwanted metal fragments out of the air-material separators associated with the wood dust conveying process. (b) A means of static charge dissipation, such as bonding or grounding, was not provided between the air-material separators and pieces of equipment which were connected by flexible non-metallic duct work on machinery such as, the approximately 6 feet of PVC hose connected to the dust collector system. The movable exhaust hose "elephant trunk" was used to vacuum the excess dust off the sanding and woodworking equipment. (c) Flexible non-metallic duct was installed on the dust collection system, approximately 6 feet of PVC hose was connected to the dust collector system. The movable exhaust hose "elephant trunk" was used to vacuum the excess dust off the sanding and woodworking equipment. (d) A spark detection system with high speed abort gate or extinguishment capability was not installed downstream of the last material entry points and upstream of the air-material separators. The Grizzly Industrial, Inc. Model G0441 3 HP cyclone dust collector was connected to machinery having an association with producing sparks, including table saw and jointer without a spark detection system with high speed abort gate. (e) Deflagration isolation or suppression systems were not provided for the inlet (dirty air) sides of the air-material separators. (f) A high-speed abort gate operating in conjunction with a spark detection system was not provided on the return air (outlet) sides of each air material separator in order to intercept and divert any burning material to atmosphere before re-entering the facility. (g) The woodworking room in the shop area - The Grizzly Industrial, Inc. Model G0441 3 HP cyclone dust collector was not equipped with an explosion prevention system and was located inside the facility. Among other methods, one feasible and acceptable abatement method to correct this hazard is to comply with the National Fire Protection Association (NFPA) 664 "Prevention for Fires and Explosions in Wood Processing and Woodworking Facilities" (2007) including, but not limited to: Install tramp metal protection to in accordance with NFPA 664 Section 7.12.2. Install static charge dissipation equipment on ductwork such as grounding and bonding accordance with NFPA 664 Section 8.2.2.2.1.8. Replace all non-metallic ductwork with metallic ductwork in accordance with NFPA 664 Section 8.2.2.2.1.1. Install explosion prevention systems which may include deflagration isolation device, to prevent explosion and deflagration venting, venting to a safe location outside, in accordance with NFPA 69 "Standard on Explosion Prevention System," 2008 edition, NFPA 68 "Standard on Explosion Protection by Deflagration Venting," 2007 edition. Locate dust collectors outside of building according to Section 8.2.2.5.1.4 of NFPA 664. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
1910.134 C01
- Issued
- Aug 14, 2009
- Abate by
- Sep 17, 2009
- Penalty
- Initial $450 · Current $450
1910.134 E01
- Issued
- Aug 14, 2009
- Abate by
- Sep 17, 2009
1910.134 F02
- Issued
- Aug 14, 2009
- Abate by
- Sep 17, 2009
1910.134 K01
- Issued
- Aug 14, 2009
- Abate by
- Sep 17, 2009
1910.1200 E01
- Issued
- Aug 14, 2009
- Abate by
- Sep 17, 2009
- Penalty
- Initial $450 · Current $450
1910.1200 E01 I
- Issued
- Aug 14, 2009
- Abate by
- Sep 17, 2009
1910.1200 G01
- Issued
- Aug 14, 2009
- Abate by
- Sep 17, 2009
1910.1200 H01
- Issued
- Aug 14, 2009
- Abate by
- Sep 17, 2009
More inspections at Paint IT the Truth Decorating, INC.
View Paint IT the Truth Decorating, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 313064917.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.