Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: P & T FILTER SALES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of P & T FILTER SALES, INC. in 904 - 17TH STREET WEST, PALMETTO, FL 34221 (NAICS 423840). OSHA activity number 313068785.

Watch P & T Filter Sales, INC. — free Get an email when a new federal OSHA severe-injury report for P & T Filter Sales, INC. is published. One employer, no account, unsubscribe in one click.
Site address
904 - 17TH STREET WEST
City
PALMETTO
State
FL
ZIP
34221
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423840
SIC code (legacy)
5085
Employees
2
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $330.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to the hazard of being struck by fragments of
Thermoplastic
Polyvinyl Chloride (PVC) plastic pipe in the event that the PVC plastic
pipe ruptures.
a.)  In the facility PVC plastic piping was used in exposed above ground
locations to transport compressed air for the operation of air operated
tools and
for cleaning purposes.  The use of PVC plastic pipe in exposed above ground
locations is not recommended by the Plastic Pipe Institute, and such use is
prohibited by ANSI/ASME B31.8-1986, Gas Transmission and Distribution
Piping Systems Standard.
Among other methods, two feasible and acceptable abatement methods to
correct this hazard are:
1) Replace all existing PVC pipes and fittings with cast iron
materials, or other types of metal piping, which are rated to
transport compressed air safely in exposed above ground
locations.
2) Replace all existing PVC pipes and fittings with shatter
resistant Acrylonitrile-Butadiene-Styrene (ABS) pipe and fittings,
which are manufactured for above ground use of compressed
air.
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.132 D01

Serious Gravity 03 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $750.00 · Current $413.00 Reduced
Recent events (2)
  • — I (S) $412.50
  • — Z (S) $750.00

1910.133 A01

Serious Gravity 03 1 instance 2 exposed
Issued
Abate by

1910.212 A05

Serious Gravity 02 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $330.00 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.219 D01

Serious Gravity 02 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $600.00 · Current $330.00 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.305 B02 I

Serious Gravity 03 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $750.00 · Current $413.00 Reduced
Recent events (2)
  • — I (S) $412.50
  • — Z (S) $750.00

1910.1200 E01

Serious Gravity 01 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $450.00 · Current $248.00 Reduced
Recent events (2)
  • — I (S) $247.50
  • — Z (S) $450.00

1910.1200 G01

Serious Gravity 01 1 instance 2 exposed
Issued
Abate by

1910.253 B04 III

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Abate by

IBT, INC