RIO HONDO, TX —
OSHA Inspection: A.A.E. MANUFACTURING COMPANY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of A.A.E. MANUFACTURING COMPANY, INC. in 28764 FM 106, RIO HONDO, TX 78583 (NAICS 337110). OSHA activity number 313139396.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.A.E. MANUFACTURING COMPANY, INC.
- Site address
- 28764 FM 106
- City
- RIO HONDO
- State
- TX
- ZIP
- 78583
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- SIC code (legacy)
- 2434
- Employees
- 42
- Ownership type
- A
Citations
15 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 25, 2009
- Abate by
- Oct 22, 2009
- Penalty
- Initial $750 · Current $450 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing, or likely to cause, death or serious physical harm to employees in that employees were exposed to flying debris in the event of a ruptured compressed air line: On or about May 18, 2009, and other times prior thereto, polyvinyl chloride (PVC) piping, 1-inch diameter, schedule 40, was used as the compressed air piping system. The PVC compressed air system was subject to rupture in the event of failure. The compressed air system was used at locations, such as, but not limited to: a.Mill shop b.Spray paint booth Among other methods, one feasible and acceptable means to correct this hazard would be to replace the existing PVC compressed air piping system with a type suitable for the transmission of compressed gases.
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.178 L01 I
- Issued
- Sep 25, 2009
- Abate by
- Oct 7, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.213 C03
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $1,250 · Current $750 Reduced
Recent events (2)
- — F (S) $750.00
- — Z (S) $1250.00
1910.213 D01
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $1,250 · Current $750 Reduced
Recent events (2)
- — F (S) $750.00
- — Z (S) $1250.00
1910.242 B
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.254 D09 III
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.304 G05
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.305 B01
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.305 B02
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.305 C04
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.305 G02 III
- Issued
- Sep 25, 2009
- Abate by
- Oct 5, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.1200 F05 I
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
- Penalty
- Initial $750 · Current $450 Reduced
Recent events (2)
- — F (S) $450.00
- — Z (S) $750.00
1910.1200 G08
- Issued
- Sep 25, 2009
- Abate by
- Oct 5, 2009
Recent events (2)
- — F (S)
- — Z (S)
1904.29 A
- Issued
- Sep 25, 2009
- Abate by
- Oct 7, 2009
Recent events (2)
- — F (O)
- — Z (O)
1910.157 E03
- Issued
- Sep 25, 2009
- Abate by
- Oct 1, 2009
Recent events (2)
- — F (O)
- — Z (O)
More inspections at A.A.E. Manufacturing Company, INC.
View A.A.E. Manufacturing Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313139396.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.