RICE LAKE, WI ·
OSHA Inspection: HOMESHIELD/FENESTRATION COMPONENTS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HOMESHIELD/FENESTRATION COMPONENTS in 311 WEST COLEMAN, RICE LAKE, WI 54868 (NAICS 332321). OSHA activity number 313176372.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOMESHIELD/FENESTRATION COMPONENTS
- Site address
- 311 WEST COLEMAN
- City
- RICE LAKE
- State
- WI
- ZIP
- 54868
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- SIC code (legacy)
- 3442
- Employees
- 288
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- May 24, 2010
- Abate by
- Jul 16, 2010
- Penalty
- Initial $2,125 · Current $1,488 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to serious burns from potential plastic dust deflagration, explosion, or other fire hazards as the result of the improper design and maintenance of the dust collection system: (a)Rolltrusion Department; The pulse cartridge dust collector for the Maxi-Blast, Inc. pressure blast mold cleaning system was located indoors without any fire, deflagration, or explosion protection systems. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE MEANS OF ABATEMENT WOULD BE TO COMPLY WITH THE GUIDELINES OUTLINED IN NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 654 "STANDARD FOR THE PREVENTION OF FIRE AND DUST EXPLOSIONS FROM THE MANUFACTURING, PROCESSING, AND HANDLING OF COMBUSTIBLE PARTICULATE SOLIDS (2006 EDITION)" Section
Recent events (2)
- · I (S) $1488.00
- · Z (S) $2125.00
1910.307 C01
- Issued
- May 24, 2010
- Abate by
- Jul 16, 2010
Recent events (2)
- · I (S)
- · Z (S)
More inspections in this industry (NAICS 332321)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313176372.