Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CURT MANUFACTURING, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CURT MANUFACTURING, INC. in 6208 INDUSTRIAL DRIVE, EAU CLAIRE, WI 54701 (NAICS 332999). OSHA activity number 313178071.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Curt Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Curt Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6208 INDUSTRIAL DRIVE
City
EAU CLAIRE
State
WI
ZIP
54701
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
Yes
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
SIC code (legacy)
3499
Employees
225
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 15 exposed
Issued
Sep 2, 2010
Abate by
Jan 7, 2011
Penalty
Initial $2,250 · Current $1,575 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to serious burns from potential metal dust deflagration,
explosion, or other fire
hazards as the result of the improper design and installation of the dust
collection system:
(a)Steel shot blast process; The following deficiencies were found with
the Farr
media dust collector for the LS Industries metal shot blast equipment:
(1)The dry type dust collector with fire, deflagration, and explosion
hazards
was located inside the production facility.
(2)The dry type dust collector included filter media.
(3)The collection bins beneath the dust collector were not bonded to reduce
the risk of accumulation of static charge.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE MEANS OF
ABATEMENT WOULD BE TO COMPLY WITH THE GUIDELINES OUTLINED IN
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 484 "STANDARD FOR
COMBUSTIBLE METALS (2006 EDITION)" INCLUDING SECTION 12.2.1.4 'DRY-
TYPE DUST COLLECTORS SHALL BE LOCATED OUTSIDE OF BUILDINGS',
SECTION 12.2.10.1 'MEDIA COLLECTORS SHALL NOT BE USED', AND
SECTION 12.2.5.10 'DUCT SYSTEMS, DUST COLLECTORS, AND DUST-
PRODUCING MACHINERY SHALL BE BONDED AND GROUNDED TO
MINIMIZE ACCUMULATION OF STATIC ELECTRIC CHARGE'.
Abatement certification and documentation are required for this item.
Abatement Schedule
STEP 1-A combination of administrative controls shall be implemented as an
interim protective measure until feasible engineering and administrative
controls can be permanently implemented.
STEP 2-A written, detailed plan of abatement shall be submitted to the Area
Directors outlining a schedule for the implementation of engineering
and/or administrative measures to control employee exposures to the
hazardous condition as referenced in this citation.  This plan shall
include,
at a minimum, target dates for the following actions which must be
consistent with the abatement dates required by this citation:
(1)Evaluation of engineering/administrative control options;
(2)Selection of optimum control methods and completion of design;
(3)Procurement, installation and operation of selected control
measures;
(4)Testing and acceptance or modification/redesign of controls;
All proposed control measures shall be approved for each particular use
by a competent certified safety professional, professional engineer, or
other technically qualified person.
STEP 3-Abatement shall have been completed by the implementation of
feasible
engineering and administrative controls upon verification of their
effectiveness in achieving compliance.
Date by Which Violation Must be Abated: STEP 1- / /
Date by Which Violation Must be Abated: STEP 2- / /
Date by Which Violation Must be Abated: STEP 3- / /
Recent events (2)
  • — I (S) $1575.00
  • — Z (S) $2250.00

1910.132 A

Serious Gravity 03 1 instance 2 exposed
Issued
Sep 2, 2010
Abate by
Sep 28, 2010
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 H01

Serious Gravity 03 1 instance 2 exposed
Issued
Sep 2, 2010
Abate by
Nov 30, 2010
Recent events (2)
  • — I (S)
  • — Z (S)

View Curt Manufacturing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313178071.