RAEFORD, NC —
OSHA Inspection: BURLINGTON INDUSTRIES V, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BURLINGTON INDUSTRIES V, LLC in 1001 TURNPIKE RD, RAEFORD, NC 28376 (NAICS 314999). OSHA activity number 313221012.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BURLINGTON INDUSTRIES V, LLC
- Site address
- 1001 TURNPIKE RD
- City
- RAEFORD
- State
- NC
- ZIP
- 28376
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314999
- SIC code (legacy)
- 2399
- Employees
- 510
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
3 citations on file for this inspection.
95012901
- Issued
- Dec 16, 2009
- Abate by
- Dec 24, 2009
- Penalty
- Initial $1,650 · Current $1,650
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to contact with hazards: a)establishment, wet finishing area - where an uninsulated base plate for a gate valve, located 5 foot, 1 inch above the floor on a steam pipe, was 292 degrees Fahrenheit. Abatement note: One feasible and acceptable abatement among others is to make a barrier guard to keep this valve assembly from accidental employee contact. [Reference ASTM C 1055-03, American Society Testing Materials- Standard Guide for Heated System Surface Conditions that Produce Contact Burn Injuries, Section 6.5: Procedures.] In the Alternative: 29 CFR 1910.132(a): Protective equipment was not provided when necessary whenever hazards capable of causing injury and impairment were encountered: a)establishment, wet finishing area - where a uninsulated base plate for a gate valve, located 5 foot, 1 inch above the floor on a steam pipe, was 292 degrees Fahrenheit.
1910.37 B02
- Issued
- Dec 16, 2009
- Abate by
- Dec 24, 2009
1910.37 B04
- Issued
- Dec 16, 2009
- Abate by
- Dec 24, 2009
More inspections at Burlington Industries V, LLC
View Burlington Industries V, LLC's full OSHA safety record →