Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COVINGTON HOMES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COVINGTON HOMES, INC. in 431 W. 500 S., JEROME, ID 83338 (NAICS 238130). OSHA activity number 313349847.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Covington Homes, INC. — free Get an email when a new federal OSHA severe-injury report for Covington Homes, INC. is published. One employer, no account, unsubscribe in one click.
Site address
431 W. 500 S.
City
JEROME
State
ID
ZIP
83338
Mailing
P.O. BOX 229, JEROME, ID 83338
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
5
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 5 exposed
Issued
Mar 10, 2010
Abate by
Mar 18, 2010
Penalty
Initial $1,500 · Current $750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to
the hazard of being struck by the
structure collapsing.
(a)West exterior wall of the shop under construction located at 431 W. 500
S. in Jerome Idaho: On
or about 01/21/2010 and at times prior thereto,  the employer did not
determine or ensured that
a load-bearing exterior wall as adequately constructed and laterally
supported prior to placing
roof trusses onto the wall, thereby exposing employees working on/around/
under the wall
and/or trusses to the hazard of being struck by the collapsing structure.
(b)The North and South gable end walls of the shop under construction
located at 431 W. 500 S. in
Jerome Idaho: On or about 01/21/2010 and at times prior thereto, the
employer did not ensure
that adequate ground bracing of the wall and first  trusses, thereby
exposing
employees working
on/around/ under the wall and/or trusses to the hazard of being struck by
the collapsing
structure.
(c)The roof of the shop under construction located at 431 W. 500S. in
Jerome Idaho: On or about
01/21/2010 and at times prior thereto, the employer did not provide
sufficient lateral and
diagonal top chordbracing, thereby exposing employees working on/around/
under the trusses to
the hazard of being struck by the collapsing structure.
Note #1: Among other methods, one feasible and acceptable abatement method
to correct this hazard would be
following the temporary bracing  requirement for roof truss installation
per the Wood Truss Council of
America/ Truss Place Institute's Building Component Safety Information
guide to Good Practices for Handling,
Installing, Restraining & Bracing of metal Plate Connected Wood Trusses'.
Note # 2: Abatement certification required for this item.
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313349847.