JEROME, ID —
OSHA Inspection: COVINGTON HOMES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of COVINGTON HOMES, INC. in 431 W. 500 S., JEROME, ID 83338 (NAICS 238130). OSHA activity number 313349847.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COVINGTON HOMES, INC.
- Site address
- 431 W. 500 S.
- City
- JEROME
- State
- ID
- ZIP
- 83338
- Mailing
- P.O. BOX 229, JEROME, ID 83338
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Mar 10, 2010
- Abate by
- Mar 18, 2010
- Penalty
- Initial $1,500 · Current $750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the structure collapsing. (a)West exterior wall of the shop under construction located at 431 W. 500 S. in Jerome Idaho: On or about 01/21/2010 and at times prior thereto, the employer did not determine or ensured that a load-bearing exterior wall as adequately constructed and laterally supported prior to placing roof trusses onto the wall, thereby exposing employees working on/around/ under the wall and/or trusses to the hazard of being struck by the collapsing structure. (b)The North and South gable end walls of the shop under construction located at 431 W. 500 S. in Jerome Idaho: On or about 01/21/2010 and at times prior thereto, the employer did not ensure that adequate ground bracing of the wall and first trusses, thereby exposing employees working on/around/ under the wall and/or trusses to the hazard of being struck by the collapsing structure. (c)The roof of the shop under construction located at 431 W. 500S. in Jerome Idaho: On or about 01/21/2010 and at times prior thereto, the employer did not provide sufficient lateral and diagonal top chordbracing, thereby exposing employees working on/around/ under the trusses to the hazard of being struck by the collapsing structure. Note #1: Among other methods, one feasible and acceptable abatement method to correct this hazard would be following the temporary bracing requirement for roof truss installation per the Wood Truss Council of America/ Truss Place Institute's Building Component Safety Information guide to Good Practices for Handling, Installing, Restraining & Bracing of metal Plate Connected Wood Trusses'. Note # 2: Abatement certification required for this item.
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
More inspections in this industry (NAICS 238130)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313349847.