FAIRMONT, WV —
OSHA Inspection: MOUNTAINEER CABINET CO., INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MOUNTAINEER CABINET CO., INC. in 1917 LOCUST AVENUE, FAIRMONT, WV 26554 (NAICS 337110). OSHA activity number 313371411.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOUNTAINEER CABINET CO., INC.
- Site address
- 1917 LOCUST AVENUE
- City
- FAIRMONT
- State
- WV
- ZIP
- 26554
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- SIC code (legacy)
- 2434
- Employees
- 38
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 12, 2010
- Abate by
- May 13, 2010
- Penalty
- Initial $1,125 · Current $1,125
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to the employees in that employees were exposed to severe burn injuries from the potential of dust explosion that could have resulted from, or have been exacerbated by lack of use of metallic duct: (a)Drawer Department: On December 09, 2009 and times prior to, employees were exposed to a dust explosion and/or fire hazard from static charge generation while collecting and blowing a combustible dust through the drawer department dust collection system. A means of static dissipation such as grounding and bonding was not provided due to the presence of a 6 inch sewer PVC pipe that was utilized to move the combustible saw dust to the dust collector. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow accepted safe practices such as but not limited to; a) install metallic/conductive duct work to prevent static electric charge generation by the airflow, b) ground and bond metallic duct work, and c) flexible ducting shall be permitted for final machine connection in a length not exceeding the minimum required for machine operation, as addressed in NFPA 664, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities, 2007 Edition, paragraph 7.9.1, 7.9.2, 8.2.2.2.1.1, and 8.2.2.2.1.2. ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
1910.134 G01 IA
- Issued
- Apr 12, 2010
- Abate by
- Apr 22, 2010
- Penalty
- Initial $1,125 · Current $788 Reduced
Recent events (2)
- — I (S) $787.50
- — Z (S) $1125.00
1910.138 A
- Issued
- Apr 12, 2010
- Abate by
- Apr 22, 2010
- Penalty
- Initial $1,125 · Current $788 Reduced
Recent events (2)
- — I (S) $787.50
- — Z (S) $1125.00
1910.178 L01 II
- Issued
- Apr 12, 2010
- Abate by
- May 6, 2010
- Penalty
- Initial $900 · Current $630 Reduced
Recent events (2)
- — I (S) $630.00
- — Z (S) $900.00
1910.303 G01 II
- Issued
- Apr 12, 2010
- Abate by
- Apr 16, 2010
- Penalty
- Initial $900 · Current $630 Reduced
Recent events (2)
- — I (S) $630.00
- — Z (S) $900.00
1910.1048 D02
- Issued
- Apr 12, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $1,125 · Current $788 Reduced
Recent events (2)
- — I (S) $787.50
- — Z (S) $1125.00
1910.1048 D03 II
- Issued
- Apr 12, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $1,125 · Current $788 Reduced
1291
Recent events (2)
- — I (S) $787.50
- — Z (S) $1125.00
1910.1048 L01 I
- Issued
- Apr 12, 2010
- Abate by
- Oct 1, 2010
- Penalty
- Initial $1,125 · Current $870 Reduced
1291
Recent events (2)
- — I (S) $870.00
- — Z (S) $1125.00
1910.1048 N01
- Issued
- Apr 12, 2010
- Abate by
- May 27, 2010
- Penalty
- Initial $1,125 · Current $788 Reduced
1291
Recent events (2)
- — I (S) $787.50
- — Z (S) $1125.00
1910.1200 H02 III
- Issued
- Apr 12, 2010
- Abate by
- Apr 22, 2010
1904.32 B03
- Issued
- Apr 12, 2010
- Abate by
- Apr 22, 2010
- Penalty
- Initial $600
Recent events (2)
- — I (O)
- — Z (O) $600.00
More inspections at Mountaineer Cabinet CO., INC.
View Mountaineer Cabinet CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313371411.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.