SOUTH CHARLESTON, WV ·
OSHA Inspection: G & S UPHOLSTERY AND REFINISHING LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of G & S UPHOLSTERY AND REFINISHING LLC in 224 7TH AVENUE, SOUTH CHARLESTON, WV 25303 (NAICS 811420). OSHA activity number 313371643.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G & S UPHOLSTERY AND REFINISHING LLC
- Site address
- 224 7TH AVENUE
- City
- SOUTH CHARLESTON
- State
- WV
- ZIP
- 25303
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811420
- SIC code (legacy)
- 7641
- Employees
- 9
- Ownership type
- Private (A)
Citations
22 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 14, 2010
- Abate by
- Jun 1, 2010
- Penalty
- Initial $600 · Current $420 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard(s) of being struck by and/or punctured by plastic projectiles from ruptured compressed air distribution system piping: (a)Third Floor: Compressed air from an Ingersol Rand Compressor was distributed at 90 PSI throughout the third floor using PVC piping that was rated according to ASTM D1785 for fluid service only and was not protected by a shatter resistant barrier as documented on January 21, 2010. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO REPLACE THE PVC PIPING WITH IRON PIPING APPROVED FOR COMPRESSED GAS SERVICE. ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
- · I (S) $420.00
- · Z (S) $600.00
1910.107 B01
- Issued
- Apr 14, 2010
- Abate by
- Apr 19, 2010
- Penalty
- Initial $450 · Current $315 Reduced
Recent events (2)
- · I (S) $315.00
- · Z (S) $450.00
1910.107 B03
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
1910.107 D02
- Issued
- Apr 14, 2010
- Abate by
- Apr 19, 2010
1910.134 C01
- Issued
- Apr 14, 2010
- Abate by
- May 17, 2010
- Penalty
- Initial $1,500 · Current $1,050 Reduced
Recent events (2)
- · I (S) $1050.00
- · Z (S) $1500.00
1910.134 D01 III
- Issued
- Apr 14, 2010
- Abate by
- Apr 19, 2010
1910.134 F02
- Issued
- Apr 14, 2010
- Abate by
- May 17, 2010
1910.134 H02 I
- Issued
- Apr 14, 2010
- Abate by
- Apr 19, 2010
1910.134 K01 II
- Issued
- Apr 14, 2010
- Abate by
- May 17, 2010
1910.134 K01 VI
- Issued
- Apr 14, 2010
- Abate by
- May 17, 2010
1910.134 K01 VII
- Issued
- Apr 14, 2010
- Abate by
- May 17, 2010
1910.134 E01
- Issued
- Apr 14, 2010
- Abate by
- May 17, 2010
- Penalty
- Initial $1,050 · Current $735 Reduced
Recent events (2)
- · I (S) $735.00
- · Z (S) $1050.00
1910.305 G02 III
- Issued
- Apr 14, 2010
- Abate by
- Apr 19, 2010
- Penalty
- Initial $600 · Current $420 Reduced
Recent events (2)
- · I (S) $420.00
- · Z (S) $600.00
1910.1052 C01
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
- Penalty
- Initial $1,500 · Current $1,050 Reduced
Recent events (2)
- · I (S) $1050.00
- · Z (S) $1500.00
1910.1052 C02
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
1910.1000 D
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
1910.134 D01 I
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
1910.1052 D02
- Issued
- Apr 14, 2010
- Abate by
- Apr 19, 2010
1910.1052 F01
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
1910.1052 F03 I
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
1910.1052 J01 I
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
1910.1052 L03 I
- Issued
- Apr 14, 2010
- Abate by
- Apr 26, 2010
More inspections at G & S Upholstery and Refinishing LLC
View G & S Upholstery and Refinishing LLC's full OSHA safety record →
More inspections in this industry (NAICS 811420)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 313371643.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.