LEADVILLE, CO ·
OSHA Inspection: GAS CONSULTANTS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of GAS CONSULTANTS, INC. in 501 HIGHWAY 24 S., LEADVILLE, CO 80461 (NAICS 541380). OSHA activity number 313416067.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GAS CONSULTANTS, INC.
- Site address
- 501 HIGHWAY 24 S.
- City
- LEADVILLE
- State
- CO
- ZIP
- 80461
- Mailing
- 7590 INDEPENDENCE DR., CLEVALAND, OH 44146
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541380
- SIC code (legacy)
- 8734
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 21, 2010
- Abate by
- May 17, 2010
- Penalty
- Initial $1,500 · Current $1,050 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire hazard which could inflict death or serious injury due to handling natural gas vehicle fuel containers: (a)Gas Consultants, Inc. at 501 Highway 24 S. in Leadville, CO: On and before January 22, 2010 the employer did not protect employees from fire and burn hazards who use, move, and transport natural gas vehicle fuel containers (NGV2-2). Two employees conduct high altitude performance tests on appliances for the appliance manufacturer. In doing so, the employees use, move, and transport cylinders of compressed natural gas. These cylinders were intended to be mounted permanently on/in vehicles for use as vehicle fuel. The employer did not ensure that the container valves and pressure relief devices were protected from damage. This condition resulted in a pressure relief valve being damaged on one of the six cylinders being loaded onto a trailer. Compressed natural gas rapidly leaked from the cylinder resulting in a fire which destroyed the Aspen Gold Building complex. (b)Gas Consultants, Inc. at 501 Highway 24 S. in Leadville, CO: On and before January 22, 2010 the employer did not protect employees from fire and burn hazards who use, move, and transport natural gas vehicle fuel containers (NGV2-2). Two employees conduct high altitude performance tests on appliances for the appliance manufacturer. In doing so, the employees use, move, and transport cylinders of compressed natural gas. These cylinders did not receive periodic in-service inspections by a qualified container inspector as referenced in ANSI/CSA NGV2a-2001 "Basic Requirements for Compressed Natural Gas Vehicle (NGV) Fuel Containers". This condition exposed employees to fire hazards associated with using compressed natural gas cylinders. (c)Gas Consultants, Inc. at 501 Highway 24 S. in Leadville, CO: On and before January 22, 2010 the employer did not protect employees from fire and burn hazards who use, move, and transport natural gas vehicle fuel containers (NGV2-2). Two employees conduct high altitude performance tests on appliances for the appliance manufacturer. In doing so, the employees use, move, and transport cylinders of compressed natural gas. These cylinders were not labeled in accordance with ANSI/CSA NGV2a-2001 "Basic Requirements for Compressed Natural Gas Vehicle (NGV) Fuel Containers". This condition exposed employees to fire hazards associated with using compressed natural gas cylinders. Abatement Note: Feasible abatement for these hazards may include the following: 1.Permanently install the compressed natural gas cylinders in a rack which protects the container valves and pressure relief devices from damage. The cylinders must be installed as required by NFPA 52"Compressed Natural Gas (CNG) Vehicular Fuel Systems". 2.Initiate and document Periodic In-Service Inspections of NGV2-2 cylinders. The containers must be inspected at least every 36 months for external damage and deterioration. The inspections must be performed and documented by a qualified container inspector in accordance with the manufacturer's recommendations and Compressed Gas Association pamphlet C-6.4. Documentation must be available to authorities upon request. 3.The CNG cylinders must be marked with the following information: -Marking in accordance with FMVSS 304 "Compressed Natural Gas Fuel Container Integrity; -NGV2-xx (xx denotes year); -Manufacturer's part number, and batch or serial number; -Statement "For Use Only With The Container Manufacturer's Approved Pressure Relief Devices and Valves". Containers without labels, or with illegible labels, must be removed from service. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement Certification Letter").
Recent events (2)
- · I (S) $1050.00
- · Z (S) $1500.00
1910.1200 E01
- Issued
- Apr 21, 2010
- Abate by
- May 17, 2010
- Penalty
- Initial $450 · Current $315 Reduced