BALTIMORE, MD —
OSHA Inspection: COUNTER TOPS & VANITIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of COUNTER TOPS & VANITIES, INC. in 315 SOUTH KRESSON STREET, BALTIMORE, MD 21224 (NAICS 337110). OSHA activity number 313456220.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COUNTER TOPS & VANITIES, INC.
- Site address
- 315 SOUTH KRESSON STREET
- City
- BALTIMORE
- State
- MD
- ZIP
- 21224
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- SIC code (legacy)
- 2434
- Employees
- 14
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
21 citations on file for this inspection.
1910.22 A01
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
- Penalty
- Initial $1,050 · Current $200 Reduced
M102
Recent events (2)
- — I (S) $200.00
- — Z (S) $1050.00
1910.23 C01
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
- Penalty
- Initial $875 · Current $150 Reduced
Recent events (2)
- — I (S) $150.00
- — Z (S) $875.00
1910.107 C06
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
- Penalty
- Initial $525 · Current $150 Reduced
Recent events (2)
- — I (S) $150.00
- — Z (S) $525.00
1910.1200 E01
- Issued
- Jan 8, 2010
- Abate by
- Feb 26, 2010
- Penalty
- Initial $875 · Current $150 Reduced
Recent events (2)
- — I (S) $150.00
- — Z (S) $875.00
1910.1200 H01
- Issued
- Jan 8, 2010
- Abate by
- Feb 26, 2010
Recent events (2)
- — I (S)
- — Z (S)
50104 A
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
- Penalty
- Initial $1,050 · Current $200 Reduced
General-duty citation text
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:09/01/09 Location:Shop Area Equipment:Enclosureless Dust Collector for the Delta Wood Shaper Condition:The dust collector was located within 20 feet of another dust collector and the flexible duct, used to convey air and materials, was nonconductive material, and was not bonded to prevent the accumulation of static electricity. (b)Date of Violation:09/01/09 Location:Shop Area Equipment:Enclosureless Dust Collector for the Table Saw Condition:The dust collector was located within 20 feet of another dust collector and the flexible duct, used to convey air and materials, was nonconductive material, and was not bonded to prevent the accumulation of static electricity. (c)Date of Violation:09/01/09 Location:Shop Area Equipment:Enclosureless Dust Collector for the Delta Edge Bander Condition:The dust collector was located within 20 feet of another dust collector and the flexible duct, used to convey air and materials, was nonconductive material, and was not bonded to prevent the accumulation of static electricity. (d)Date of Violation:09/01/09 Location:Shop Area Equipment:Enclosureless Dust Collector for the Holz Her 1255 Vertical Panel Saw Condition:A flexible duct, to convey air and materials, was nonconductive material, and was not bonded to prevent the accumulation of static electricity. (e)Date of Violation:09/01/09 Location:Shop Area Equipment:Enclosureless Dust Collector for the High Pak Midwest Saw Condition:A flexible duct, to convey air and materials, was nonconductive material, and was not bonded to prevent the accumulation of static electricity. (f)Date of Violation:09/01/09 Location:Shop Area Equipment:Enclosureless Dust Collector for the Grainger Model 1Z863 B Router Condition:A flexible duct, to convey air and materials, was nonconductive material, and was not bonded to prevent the accumulation of static electricity. (g)Date of Violation:09/01/09 Location:Shop Area Equipment:Enclosureless Dust Collector for the Cut Off Saw Condition:A flexible duct, to convey air and materials, was nonconductive material, and was not bonded to prevent the accumulation of static electricity. Among other methods, one feasible and acceptable abatement method to correct this hazard is to relocate the dust collection systems at a minimum of 20 feet from an area, routinely occupied by personnel, which means a lunch room, meeting place, or any routinely staffed work station. Also, the dust collection systems, must by located at least 20 feet from any means of egress and maintain at least 20 feet from each other. The collected dust must by removed daily or more frequently to ensure efficient operation. Installation, operation, and maintenance of the enclosureless dust collection systems must meet all applicable standards including, but not limited to, NFPA 664. Abatement documentation (photographs, receipts, copies of programs, training certification, etc.) is required for this item.
Recent events (2)
- — I (S) $200.00
- — Z (S) $1050.00
50104 A
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
- Penalty
- Initial $875 · Current $150 Reduced
General-duty citation text
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:09/01/09 Location:Shop Area Condition:An employee operates a Clark C 50 B Type 6 forklift without a seat belt. Among other methods, one feasible and acceptable abatement method to correct this hazard is to purchase and install a retro-fit kit that contains a seat belt, hip restraints, and a latch. Abatement documentation (photographs, receipts, copies of programs, training certification, etc.) is required for this item.
Recent events (2)
- — I (S) $150.00
- — Z (S) $875.00
1910.22 D01
- Issued
- Jan 8, 2010
- Abate by
- Feb 26, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.132 D02
- Issued
- Jan 8, 2010
- Abate by
- Feb 26, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.132 F04
- Issued
- Jan 8, 2010
- Abate by
- Feb 26, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.134 C02 I
- Issued
- Jan 8, 2010
- Abate by
- Feb 26, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.157 E02
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.303 B02
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.305 B01 II
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.305 G01 IV
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.305 G02 III
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.305 J01 I
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
Recent events (2)
- — I (O)
- — Z (O)
1904.4 A
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
Recent events (2)
- — I (O)
- — Z (O)
50405 B01
- Issued
- Jan 8, 2010
- Abate by
- Jan 19, 2010
Recent events (2)
- — I (O)
- — Z (O)
50406 A01
- Issued
- Jan 8, 2010
- Abate by
- Feb 4, 2010
Recent events (2)
- — I (O)
- — Z (O)
1910.305 B02 I
- Issued
- Dec 23, 2009
- Abate by
- Jan 4, 2010
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Counter Tops & Vanities, INC.