Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COOK COMPOSITES AND POLYMERS CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COOK COMPOSITES AND POLYMERS CO. in 340 RAILROAD STREET, SAUKVILLE, WI 53080 (NAICS 325211). OSHA activity number 313523375.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cook Composites and Polymers CO. — free Get an email when a new federal OSHA severe-injury report for Cook Composites and Polymers CO. is published. One employer, no account, unsubscribe in one click.
Site address
340 RAILROAD STREET
City
SAUKVILLE
State
WI
ZIP
53080
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
SIC code (legacy)
2821
Employees
34
Ownership type
A

10 citations on file for this inspection.

1910.106 H07 IA

Other-than-serious Gravity 03 1 instance 4 exposed
Issued
Mar 8, 2010
Abate by
Mar 18, 2010
Penalty
Initial $1,875
29 CFR 1910.106(h)(7)(i)[a]: Precautions were not taken to prevent the
ignition of flammable
vapors. Sources of ignition include but are not limited to open flames;
lighting; smoking; cutting
and welding; hot surfaces; frictional heat; static, electrical and
mechanical sparks; spontaneous
ignition, including heat-producing chemical reactions; and radiant heat.
(a)The employer did not use non-spark producing tools in areas listed by
the
employer as Class I Division I locations. Process Technicians in building
20 used
a T-Wrench tool(s) that were not made of non-sparking material to secure
and
unsecure manway bolts on kettle reactor vessels and blend tank manway
covers.
This exposed process technicians and other employees to an explosion and
fire
hazard, in-that a spark can potentially be produced while using the tool,
igniting
potentially present flammable vapors from the process vessel during
charging
process.
Certification, with date and method of abatement required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — I (O)
  • — Z (S) $1875.00

1910.119 D03 I

Serious Gravity 10 5 instances 9 exposed
Issued
Mar 8, 2010
Abate by
Apr 10, 2010
Penalty
Initial $4,500 · Current $2,300 Reduced
29 CFR 1910.119(d)(3)(i):  Process safety information pertaining to the
equipment in the process
did not include the elements specified in 29 CFR 1910.119(d)(3)(i)(A)
through (H):
(a) Reactor K-3, P&ID #D.81.000.F.107:
1.Interlocks installed on the process were not identified on the P&ID. Such
as, but not limited to shut off feeds on loss of agitation, shut off of
nitrogen on high pressure and turn on cooling on high pressure in the
vessel.
(b) Reactor K-4, P&ID #D.81.000.F.110:
1.Rupture disc rating is shown to be 30 PSIG. The actual rupture disc
rating
is 15 PSIG and was installed in September of 2008.
2.The rated design pressure of the K-4 vessel is shown to be 30 PSIG. The
design pressure had been derated to 15 PSIG. The working pressure of the
vessel was shown to be 20 PSIG and is reflected to be 12.5 PSIG in CCP-
04-081-REF-05 Operating Limits and Corrective actions reference
document.
(c) Reactor K-5, P&ID #D.81.000.F.113:
1.The P&ID does not reflect the design pressure of the vessel.
2.Interlocks installed on the process were not identified on the P&ID.
Interlocks installed on the system and not identified are, but not limited
to shut off feeds on loss of agitation, shut off of nitrogen on high
pressure
and turn on cooling on high pressure in the vessel.
(d) Reactor K-7, P&ID #D.81.020.F.115:
1.The rated design pressure of the K-7 vessel is not identified on the
P&ID.
2.The rupture disc pressure setting is shown to be 30 PSIG on the P&ID.
The actual pressure setting is set to 40 PSIG.
3.Interlocks installed on the process were not identified on the P&ID.
Interlocks installed on the system and not identified are, but is not
limited
to shut off feeds on loss of agitation, shut off nitrogen on high pressure
and turn on cooling on high pressure in the vessel.
(e) Hot Oil System Distribution System, P&ID #D.81.000.U.307:
1.The rated design pressure of the vessel was not identified on the P&ID.
2.The working pressure of the Hot Oil Boiler was not identified.
3.The PSV (Pressure Safety Valve) did not identify the relief set point.
Certification, and documentation/evidence of abatement is required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — I (S) $2300.00
  • — Z (S) $4500.00

1910.119 D03 II

Serious Gravity 10 2 instances 9 exposed
Issued
Mar 8, 2010
Abate by
Apr 25, 2010
Penalty
Initial $6,300 · Current $3,200 Reduced
29 CFR 1910.119(d)(3)(ii):  The employer did not document that the
equipment in the process
complied with recognized and generally accepted good engineering practices:
(a)The employer did not document that Thin Tank T-104 Condenser complied
with
recognized and generally accepted good engineering practices (RAGAGEP), in-
that the Form U-3 Manufacturer's Certificate of Compliance Covering
Pressure
Vessels was not maintained.
(b)The Kettle 7 (K-7) Decanter did not have an independent relief device
installed
on the vessel, nor was an open relief path assured through the method of
carsealed open intervening valves.
Certification, and documentation/evidence of abatement is required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — I (S) $3200.00
  • — Z (S) $6300.00

1910.119 E03 III

Serious Gravity 01 1 instance 9 exposed
Issued
Mar 8, 2010
Abate by
Apr 10, 2010
Penalty
Initial $1,125 · Current $600 Reduced
29 CFR 1910.119(e)(3)(iii):  The process hazard analysis did not address
the engineering and
administrative controls applicable to the hazards and their
interrelationship, such as, appropriate
application of detection methodologies to provide early warning of
releases:
(a)Process Hazard Analysis (PHA) Safe Guards reference Generic and Inherent
Safeguards to protect against or mitigate process material releases. The
specific
Generic and Inherent safe guards listed in Table A.3 and that apply to the
node
item are not identified.
(b)Node 13 Kettle startup (k1/k2/k3/k4) - Pit Cover and Water Supply: Node
Item
13.4 does not list a safe guard for if water pressure goes below the 25
PSIG
operating limit.
(c)Node 17 Charging Bulk liquids to K1-K7 Kettles and Associated Weigh
Tanks via
Mass Meters: Node item 17.7 deviation states if a wrong charge quantity is
entered into the mass meter control panel a release of material could
occur. The
safeguard does not identify that a high alarm level warning device is
integrated
into the weigh tank.
Certification, with date and method of abatement required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.
Recent events (2)
  • — I (S) $600.00
  • — Z (S) $1125.00

1910.119 E05

Serious Gravity 01 1 instance 9 exposed
Issued
Mar 8, 2010
Abate by
Jun 8, 2010
Penalty
Initial $1,125 · Current $600 Reduced
29 CFR 1910.119(e)(5):  The employer did not establish a system to assure
that the process
hazard analysis team's recommendations are resolved in a timely manner and
that the resolution
is documented:
(a)The employer did not document that PHA recommendations were resolved in
a
timely manner.  Recommendations from the 1998 initial PHA could not be
verified as closed and what the final resolution to the recommendation was.
Certification, with date and method of abatement required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — I (S) $600.00
  • — Z (S) $1125.00

1910.119 E06

Serious Gravity 10 1 instance 9 exposed
Issued
Mar 8, 2010
Abate by
Apr 10, 2010
Penalty
Initial $6,300 · Current $3,200 Reduced
29 CFR 1910.119(e)(6):  The employer did not ensure after the initial
process hazard analysis
that the process hazard analysis was updated and revalidated at least
every five (5) years by a
team meeting the requirements of 29 CFR 1910.119(e)(4):
(a)The employer did not accomplish a Process Hazard Analysis (PHA)
revalidation
at least every five years in that the 1998 initial PHA revalidation was
not begun
until May of 2008 and not completed as of March, 2010.
Certification, and documentation/evidence of abatement is required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — I (S) $3200.00
  • — Z (S) $6300.00

1910.119 F01 IB

Serious Gravity 03 1 instance 9 exposed
Issued
Mar 8, 2010
Abate by
Apr 10, 2010
Penalty
Initial $1,875 · Current $1,000 Reduced
29 CFR 1910.119(f)(1)(i)(B):  The employer did not develop written
operating procedures
covering the steps for each operating phase of normal operations:
(a)The employer did not have an operating procedure for Draining of
Knock-Out
Boxes to the TSD facility.
Certification, with date and method of abatement required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $1875.00

1910.119 F01 II

Other-than-serious Gravity 03 2 instances 9 exposed
Issued
Mar 8, 2010
Abate by
Apr 10, 2010
Penalty
Initial $1,875
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — I (O)
  • — Z (S) $1875.00

1910.119 J04 I

Serious Gravity 10 1 instance 9 exposed
Issued
Mar 8, 2010
Abate by
Mar 11, 2010
Penalty
Initial $6,300 · Current $3,200 Reduced
29 CFR 1910.119(j)(4)(i):  Inspections and tests were not performed on
process equipment to
maintain its mechanical integrity:
(a)The employer did not assure the ongoing mechanical integrity of the
T-104
Condenser (Spiral Heat Exchanger), serial number 22450, in that no
mechanical
integrity inspection and test were accomplished on the vessel.
No certification required.  Violation Abated.on
Recent events (2)
  • — I (S) $3200.00
  • — Z (S) $6300.00

1910.119 L02 II

Serious Gravity 10 3 instances 18 exposed
Issued
Mar 8, 2010
Abate by
Apr 10, 2010
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.119(l)(2)(ii):  The written procedures to manage changes did
not assure that the
impact of the change on safety and health was addressed prior to any
change:
(a)The employer did not accomplish a management of change (MOC) when the
K-4
vent line rupture disc was changed from a 30 PSIG rupture disc to a 15 PSIG
rupture disc.
(b)The employer did not accomplish a management of change (MOC) when the
K-3
vent line rupture disc was changed from a 30 PSIG rupture disc to a 15 PSIG
rupture disc.
(c)A reduction in staffing levels was accomplished without implementing a
Management of Change (MOC) to ensure that processes were adequately staffed
to handle monitoring of covered processes.
Certification, and documentation/evidence of abatement is required.
Certification of abatement is required by 29 CFR Part 1903 and is to be
submitted within ten (10)
calendar days after the abatement date.ment
Recent events (2)
  • — I (S) $2250.00
  • — Z (S) $4500.00

View Cook Composites and Polymers CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313523375.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.