MILWAUKEE, WI —
OSHA Inspection: RCS SYSTEMS, INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of RCS SYSTEMS, INC. in 7075 W. PARKLAND CT., MILWAUKEE, WI 53223 (NAICS 337215). OSHA activity number 313524514.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RCS SYSTEMS, INC.
- Site address
- 7075 W. PARKLAND CT.
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53223
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337215
- SIC code (legacy)
- 2541
- Employees
- 70
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Feb 11, 2010
- Abate by
- Jul 29, 2011
- Penalty
- Initial $700
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to wood dust explosion, deflagration or other fire hazards: (a)The Torit/Donaldson model 276 RFW 10 dust collector, used to collect combustible wood dust, did not have a means to prevent a fire in the dust collector from traveling upstream or downstream (via air recirculation) into the plant. Feasible abatement methods include complying with Chapter 8 of NFPA 664 Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities, such as but not limited to: (1) installing spark detection equipment and abort gates in conformance with NFPA 72 National Fire Alarm Code in order to divert any burning material to atmosphere before it can enter the plant; and (2) install isolation devices to prevent propagation of fire and deflagration both upstream and downstream into the plant from the dust collector. Commonly used isolation devices include abort gates, slide gates, back blast dampers, and flame front extinguishers. Certification, with date and method of abatement required. Certification of abatement is required by 29 CFR Part 1903 and is to be submitted within ten (10) calendar days after the abatement date.ment
Recent events (3)
- — P (O)
- — I (O)
- — Z (S) $700.00
More inspections at RCS Systems, INC.
View RCS Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337215)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313524514.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.