MILWAUKEE, WI —
OSHA Inspection: REXNORD INDUSTRIES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of REXNORD INDUSTRIES, LLC in 3001 WEST CANAL STREET, MILWAUKEE, WI 53208 (NAICS 333612). OSHA activity number 313524829.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REXNORD INDUSTRIES, LLC
- Site address
- 3001 WEST CANAL STREET
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53208
- Mailing
- P.O. BOX 492, MILWAUKEE, WI 53201
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333612
- SIC code (legacy)
- 3566
- Employees
- 800
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 18, 2010
- Abate by
- Jun 5, 2010
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in the Mold Department in that: (b)Pneumatic tools incompatible with compressed oxygen gas were connected to the shop-modified compressed oxygen gas piping system exposing employee to the hazard of fire and explosion. Among other methods, feasible and acceptable means of abatement would be to: 1.Identify the contents of pipes and valves by color coding or affixing tags to pipes and valves as provided in ANSI Standard A13.1, Scheme for the Identification of Piping Systems and the Compressed Gas Association Pamphlet G-4.4, Industrial Practices for Gaseous Oxygen Transmission and Distribution Piping Systems. 2.Ensure interconnecting equipment compatibility as provided in NFPA-50, Standard for Bulk Oxygen Systems at Consumers Sites. Thereby, connections to compressed air piping and compressed oxygen gas piping must not be interchangeable. Certification, and documentation/evidence of abatement is required. Certification of abatement is required by 29 CFR Part 1903 and is to be submitted within ten (10) calendar days after the abatement date.ment
Recent events (2)
- — I (S) $2500.00
- — Z (S) $5000.00
More inspections at Rexnord Industries, LLC
View Rexnord Industries, LLC's full OSHA safety record →
More inspections in this industry (NAICS 333612)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313524829.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.