OSHA Inspection: RON KING DBA RON KING CONSTRUCTION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RON KING DBA RON KING CONSTRUCTION in 5082 MEADOWBROOK DRIVE, TRINITY, NC 27370 (NAICS 238130). OSHA activity number 313600678.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RON King DBA RON King Construction for free Get an email when a new federal OSHA severe-injury report for RON King DBA RON King Construction is published. One employer, no account, unsubscribe in one click.
Site address
5082 MEADOWBROOK DRIVE
City
TRINITY
State
NC
ZIP
27370
Mailing
1818 WOODJOO DRIVE, ASHEBORO, NC 27204
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
3
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

95012901

Serious 1 instance 3 exposed
Issued
Oct 13, 2009
Abate by
Oct 16, 2009
Penalty
Initial $1,050 · Current $600 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish to each of his employees conditions of employment
and a place of em ployment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to
employees in that employees were exposed to the potential of being struck
by falling trusses due to a failure to
follow the manufacturer's recommendation or the Building Component Safety
Information (BCSI B1, B2, or
B3) Guide to Good Practice for Handling, Installing, and Bracing of Metal
Plate Connected Wood Trusses:
a)jobsite - on or about Sept 8, 2009 when approximately thirty-seven (37)
sixth-seven ft.
long wooden scissor trusses collapsed inward into the building when the
employer failed
to ensure that the following manufactures's recommendations, Wood Truss
Council of
America (WTCA), and those of the BCSI 1-3 were not followed:
(1)The employer failed to ensure that the top chord temporary lateral
restraint
spacing of four feet on center for truss spans of 60' to 80'  was being
maintained; and not at 13 feet on center.
(2)The employer failed to ensure that the web member plane bracing spacing
was
set at 10 -15 feet on center using one w-brace which made the spacing of
the
restraint 33 ft. center to center exceeded the allowable spacing.
(3)The employer failed to ensure that the bottom chord bracing of 10 - 15
feet on
center using 2,4,12 feet members that only two brace were utilized making
the
spacing of the restraint between eave and first restraint 26 feet
exceeding the
allowable spacing.
(4)The employer failed to follow the handout provide on "Long Span Truss
Installation" of Wood Truss Council of America (WTCA) that highly
recommended installing temporary center supports to reduce the stresses on
the
truss chords during erection; that is to install only a few trusses at a
time
then
sheet, and not install all the trusses then sheet only one side before the
other
side.
(5)The employer failed to follow the handout provided on "Long Span Truss
Installation" of WTCA that required using 2x4's that were stress grade
lumber
with two nails at each end of the bracing, and not 1x4 construction grade
lumber with one nail at each end to protect against rotation.
(6)The employer failed to follow the handout in BCSI 1-3 that provided
detailed
requirements and instructions of bracing the gable trusses; the employer
only
braced four out of the nine gable trusses to the ground.
[ Reference;  Building Component Safety Information ( BCSI B1, B2, and
B3), Guide
to Good Practice for Handling, Installing, and Bracing of Metal Plate
Connected Wood
Trusses]
ABATEMENT NOTE:  Among other methods, one feasible and acceptable abatement
method to correct this hazard would be to follow the manufacturer's and
the BCSI 1-3
recommendations.