FULTON, MS —
OSHA Inspection: MUELLER PACKAGING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MUELLER PACKAGING, LLC in 409 MUELLER ROAD, FULTON, MS 38843 (NAICS 331421). OSHA activity number 313626608.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MUELLER PACKAGING, LLC
- Site address
- 409 MUELLER ROAD
- City
- FULTON
- State
- MS
- ZIP
- 38843
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331421
- SIC code (legacy)
- 3351
- Employees
- 26
- Ownership type
- A
Citations
15 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 25, 2010
- Abate by
- Feb 19, 2010
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards; (a)On or about August 26, 2009 at the worksite, a six (6) foot fiberglass step ladder had two (2) damaged steps. Reference for ladders -- ANSI A14.5-2000 Portable Reinforced Plastic - Safety Requirements, Section 9.4 Care, sub-sections 9.4.1 Inspection, and 9.4.2 Damaged Ladders. Among others, one feasible and useful abatement method to correct this hazard is to: Is to follow ANSI A14.5 which requires to conduct periodic (daily) inspections of ladders and remove damaged ladders from service.
Recent events (2)
- — F (S) $2000.00
- — Z (S) $2000.00
1910.23 C01
- Issued
- Jan 25, 2010
- Abate by
- Mar 12, 2010
- Penalty
- Initial $2,000 · Current $2,000
Recent events (2)
- — F (S) $2000.00
- — Z (S) $2000.00
1910.23 D01
- Issued
- Jan 25, 2010
- Abate by
- Mar 12, 2010
Recent events (2)
- — F (S)
- — Z (S)
1910.147 C04 I
- Issued
- Jan 25, 2010
- Abate by
- Mar 12, 2010
- Penalty
- Initial $3,500 · Current $3,500
Recent events (2)
- — F (S) $3500.00
- — Z (S) $3500.00
1910.179 H04
- Issued
- Jan 25, 2010
- Abate by
- Mar 12, 2010
- Penalty
- Initial $1,500 · Current $1,500
Recent events (2)
- — F (S) $1500.00
- — Z (S) $1500.00
1910.184 C02
- Issued
- Jan 25, 2010
- Abate by
- Jan 28, 2010
- Penalty
- Initial $2,000 · Current $2,000
Recent events (2)
- — F (S) $2000.00
- — Z (S) $2000.00
1910.212 B
- Issued
- Jan 25, 2010
- Abate by
- Feb 19, 2010
- Penalty
- Initial $2,000 · Current $2,000
Recent events (2)
- — F (S) $2000.00
- — Z (S) $2000.00
1910.242 B
- Issued
- Jan 25, 2010
- Abate by
- Feb 19, 2010
- Penalty
- Initial $2,000 · Current $2,000
Recent events (2)
- — F (S) $2000.00
- — Z (S) $2000.00
1910.303 G02 I
- Issued
- Jan 25, 2010
- Abate by
- Feb 4, 2010
- Penalty
- Initial $5,000 · Current $5,000
Recent events (2)
- — F (S) $5000.00
- — Z (S) $5000.00
1910.305 G02 II
- Issued
- Jan 25, 2010
- Abate by
- Feb 19, 2010
- Penalty
- Initial $2,500 · Current $2,500
Recent events (2)
- — F (S) $2500.00
- — Z (S) $2500.00
1910.178 A04
- Issued
- Jan 25, 2010
- Abate by
- Mar 12, 2010
- Penalty
- Initial $10,000 · Current $2,250 Reduced
Recent events (2)
- — F (R) $2250.00
- — Z (R) $10000.00
1910.303 F02
- Issued
- Jan 25, 2010
- Abate by
- Feb 19, 2010
- Penalty
- Initial $10,000 · Current $2,250 Reduced
Recent events (2)
- — F (R) $2250.00
- — Z (R) $10000.00
1910.305 G01 IVA
- Issued
- Jan 25, 2010
- Abate by
- Mar 12, 2010
- Penalty
- Initial $10,000 · Current $2,250 Reduced
Recent events (2)
- — F (R) $2250.00
- — Z (R) $10000.00
1910.305 G02 III
- Issued
- Jan 25, 2010
- Abate by
- Feb 19, 2010
- Penalty
- Initial $10,000 · Current $2,250 Reduced
Recent events (2)
- — F (R) $2250.00
- — Z (R) $10000.00
1910.305 B02
- Issued
- Jan 25, 2010
- Abate by
- Feb 4, 2010
Recent events (2)
- — F (O)
- — Z (O)
More inspections at Mueller Packaging, LLC
View Mueller Packaging, LLC's full OSHA safety record →
More inspections in this industry (NAICS 331421)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313626608.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.