OSHA Inspection: MUSTANG ENGINEERING, L.P.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of MUSTANG ENGINEERING, L.P. in TETCO INTERCONNECT, 5354 MYER ROAD, TERRY, MS 39170 (NAICS 541330). OSHA activity number 313627978.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mustang Engineering, L.P. — free Get an email when a new federal OSHA severe-injury report for Mustang Engineering, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
TETCO INTERCONNECT, 5354 MYER ROAD
City
TERRY
State
MS
ZIP
39170
Mailing
16001 CLARK TEN PLACE, HOUSTON, TX 77084
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541330
SIC code (legacy)
8711
Employees
4
Ownership type
A

1 citation on file for this inspection.

1910.132 A

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Jan 11, 2010
Abate by
Jan 14, 2010
Penalty
Initial $49,500 · Current $7,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to hazard of being struck by:
(a)  TETCO Metering Station - On or about July 12, 2009 employees were
exposed to
the hazard of being struck by high pressure gas, flying projectiles and
other debris from
the rupture of piping and pressure vessels during leak testing of gas
metering stations that
were pressurized with nitrogen gas. Employees on site during these
pneumatic
pressure
tests were not protected from the hazards by the use of:
a. Hydrostatic testing unless analysis demonstrate that hydrostatic
testing is not
feasible
b. Remove employees from the area
Among other methods, one feasible and acceptable abatement method to
correct this
hazard is to:  Use hydrostatic (liquid) testing when feasible as specified
in ASME B31.1-
2007, move non-essential employees to a safe distance as specified in the
Midcontinent
Express document entitled "Specifications for Nitrogen Pressure Testing"
and provide a
physical barrier where feasible to protect employees from flying
projectiles. Gradually
increase pressure in steps until test pressure is reached.
Recent events (2)
  • — F (O) $7000.00
  • — Z (W) $49500.00

View Mustang Engineering, L.P.'s full OSHA safety record →