OSHA Inspection: BEACON SIGNS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BEACON SIGNS in 5 MI N CONWAY, MISSION, TX 78572 (NAICS 339950). OSHA activity number 313636417.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Beacon Signs for free Get an email when a new federal OSHA severe-injury report for Beacon Signs is published. One employer, no account, unsubscribe in one click.
Establishment
BEACON SIGNS
Site address
5 MI N CONWAY
City
MISSION
State
TX
ZIP
78572
Mailing
1841 N ALAMO, ALAMO, TX 78516
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
SIC code (legacy)
3993
Employees
5
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 26, 2010
Abate by
Apr 7, 2010
Penalty
Initial $1,500 · Current $900 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing, or likely to cause, death or serious physical harm to
employees in that employees
were exposed to fall hazards and electrical hazards:
On October 1, 2009, and at times prior thereto, employees utilized and
operated
a vehicle-mounted aerial lift with the deficiencies listed below. The
employees
were exposed to fall hazards and electrical hazards:
a.The flooring of the personnel basket was cut out in a large U-shaped
pattern large enough for employees to fall through.
b.The personnel basket was a shop-made basket which had not been
approved by the manufacturer of the aerial lift device.
c.The electrical wiring and connections did not have their protective
coverings; terminations were exposed to environmental damage.
d.Pulleys and belts on the aerial lift did not have their protective guard.
e.The wire rope/cable of the aerial lift was worn and frayed; there were
numerous broken strands of wire rope.
f.Electrical wiring from under the interior dashboard of the Ford F-350
truck was permitted to dangle.
Among other methods, one feasible and acceptable abatement method to
correct
these hazards is to perform maintenance and conduct and record inspections
and
tests on the vehicle-mounted aerial lift as recommended by the manufacturer
and/or at least annually in accordance with the American National Standards
Institute(ANSI) American National Standard for Vehicle-Mounted Elevating
and
Rotating Aerial Devices, as stipulated below:
1.Section 8 Responsibilities for the Owners and Users 8.2 Inspection and
Testing Classifications 8.2.2 Regular inspections and Tests.
2.Items determined by the user based on manufacturer for each specific
aerial device shall be inspected for defects. Inspection and tests referred
to as critical in the manufacturers's manual shall be strictly adhered to.
3.Ensuring the following tests and inspections are performed by the
operator
once daily, prior to first use:
A.Operating controls and associated mechanisms for conditions
interfering with proper operation
B.Visual and audible safety devices for malfunction
C.Hydraulic or pneumatic systems for observable deterioration or
excessive leakage
D.Fiberglass and other insulating components for visible damage or
contamination
E.Missing or illegible operational markings
F.Electrical apparatus for malfunction, signs of excessive
deterioration, dirt, and moisture accumulation.
4.Any suspected items shall be carefully examined and determination made
by a qualified person as to whether they constitute a safety hazard. All
unsafe items shall be replaced or repaired before use.
Recent events (2)
  • · I (S) $900.00
  • · Z (S) $1500.00

1910.23 A08 II

Serious Gravity 02 1 instance 2 exposed
Issued
Mar 26, 2010
Abate by
Apr 1, 2010
Penalty
Initial $600 · Current $360 Reduced
Recent events (2)
  • · I (S) $360.00
  • · Z (S) $600.00

1910.67 C02 I

Serious Gravity 02 1 instance 2 exposed
Issued
Mar 26, 2010
Abate by
Apr 1, 2010
Penalty
Initial $600 · Current $360 Reduced
Recent events (2)
  • · I (S) $360.00
  • · Z (S) $600.00

1910.254 D09 III

Serious Gravity 05 1 instance 2 exposed
Issued
Mar 26, 2010
Abate by
Apr 1, 2010
Penalty
Initial $1,050 · Current $630 Reduced
Recent events (2)
  • · I (S) $630.00
  • · Z (S) $1050.00

1910.141 B01 VI

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Mar 26, 2010
Abate by
Apr 1, 2010
Recent events (2)
  • · I (O)
  • · Z (O)

View Beacon Signs's full OSHA safety record →