On , OSHA opened a planned safety inspection of MURFIN DRILLING COMPANY, INC. - RIG 25 in T 19S; R 44W, KIOWA, CO 81071 (NAICS 213111). OSHA activity number 313719734.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MURFIN DRILLING COMPANY, INC. - RIG 25
- Site address
- T 19S; R 44W
- City
- KIOWA
- State
- CO
- ZIP
- 81071
- Mailing
- 250 N WATER, SUITE 300, WICHITA, KS 67202
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 11, 2010
- Abate by
- Jun 17, 2010
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment or a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards: a)On or about May 19, 2010, employees were exposed to fall hazards where the anchor for the Geronimo line was not rated as being capable of withstanding a pull of 3000 lbs, as recommended by the manufacturer. The Operator's Manual for the Geronimo Emergency Escape Device states: "The anchor to which you secure the lower end of the cable must be able to withstand a pull of at least 3000 pounds." American Petroleum Institute Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations (API RP 54) states "The ground anchor point should be able to withstand a pull of at least 3000 lb." b)On or about May 19, 2010, employees were exposed to fall hazards where the wire rope used for the Geronimo line was kinked at the top, approximately five feet from where it was attached to the derrick mast. The Operator's Manual for the Geronimo Emergency Escape Device states: "Make sure the cable has no kinks or frayed areas." American Petroleum Institute Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations (API 54) states that wire rope used for an auxiliary escape be in "good condition." Among other methods, one feasible and acceptable method to correct this hazardous condition would be to anchor the escape line per manufacturer's recommendations and to regularly inspect the wire rope used for the escape device and replace it as necessary. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — I (O) $1500.00
- — Z (S) $1500.00
5(a)(1)
- Issued
- Jun 11, 2010
- Abate by
- Jun 17, 2010
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment or a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards: a)On or about May 19, 2010, and at times prior, employees were exposed to fall hazards where the snap hook for the fall protection system on the derrick mast was damaged and did not close as designed. American Petroleum Institute Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations (API RP 54), Section 5.5, Fall Protection, states "Manufacturer's instructions for inspection and replacement should be followed." Among other methods, one feasible and acceptable method to correct this hazardous condition would be to replace defective or damaged fall protection equipment as necessary. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (O) $1500.00
- — Z (S) $1500.00
1910.133 A03
- Issued
- Jun 11, 2010
- Abate by
- Jun 17, 2010
- Penalty
- Initial $900 · Current $900
Recent events (2)
- — I (O) $900.00
- — Z (S) $900.00
1910.176 C
- Issued
- Jun 11, 2010
- Abate by
- Jun 17, 2010
- Penalty
- Initial $900 · Current $900
Recent events (2)
- — I (S) $900.00
- — Z (S) $900.00
1910.23 C01
- Issued
- Jun 11, 2010
- Abate by
- Jun 17, 2010
- Penalty
- Initial $3,000 · Current $3,000
Recent events (2)
- — I (S) $3000.00
- — Z (R) $3000.00