Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOSE DIAZ

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOSE DIAZ in 3505 JOLLY ROAD, AYDEN, NC 28513 (NAICS 111211). OSHA activity number 313821498.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jose Diaz — free Get an email when a new federal OSHA severe-injury report for Jose Diaz is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE DIAZ
Site address
3505 JOLLY ROAD
City
AYDEN
State
NC
ZIP
28513
Mailing
4549 MOBLEY BRIDGE ROAD, GRIMESLAND, NC 27837
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Migrant workforce
X
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
111211
SIC code (legacy)
0139
Employees
40
Ownership type
A

13 citations on file for this inspection.

95012901

Serious Gravity 05 7 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010
Penalty
Initial $1,500 · Current $1,000 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:
The employer did not furnish each of his employees conditions of
employment and a place of employment free
from recognized hazards that were causing or likely to cause death or
serious physical harm to employees in
that employees were exposed to electrical hazards:
a) Temporary migrant labor camp, 3505 Jolly Road, Ayden, NC - twelve
migrant farm workers were
occupying a temporary migrant labor camp where the following electrical
hazards existed:
1) Electrical outlets, located less than six feet from a water source in
the kitchen, were not ground fault
protected.
2) Light fixtures and wall outlets that were not properly secured and wall
outlets missing covers allowed
for live wires rated at 110 volts to be exposed in bedrooms and in kitchen
3) Temporary electrical wiring was being used in lieu of permanent wiring
to supply power to an
exterior light, cord was run through pinch points at a window.
4) Electric stove was not grounded.
b) Temporary migrant labor camp, 3409 Jolly Road, Ayden, NC - six migrant
farm workers were occupying a
temporary migrant labor camp where the following electrical hazards
existed:
1) Electric stove was not grounded.
2) A temporary electrical cord, plugged into a non-gfci outlet and running
along the counter behind the
kitchen sink, was used to supply electricity to the refrigerator.
3) A temporary electrical cord, held together by black electrical tape,
was being used to supply
electricity to an overhead light in the living area.
ABATEMENT NOTICE:
Among others, one feasible and acceptable method of abating these
violations
is to eliminate all temporary
wiring being used on a permanent basis and to have all corrections made in
accordance with the NEC and local
building code requirements.
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $1500.00

950225 D

Serious Gravity 05 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010
Penalty
Initial $1,500 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $1500.00

950225 F

Serious Gravity 05 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010
Penalty
Initial $1,500 · Current $1,000 Reduced
Recent events (2)
  • — I (S) $1000.00
  • — Z (S) $1500.00

950225 E

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010

950225 G05

Other-than-serious 1 instance 12 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010

950225 H

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010

950226 A

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010
Penalty
Initial $2,000 · Current $1,620 Reduced
Recent events (2)
  • — I (O) $1620.00
  • — Z (O) $2000.00

1910.142 B01

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010

1910.142 B04

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010

1910.142 B08

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010

1910.142 F01 II

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010

1910.142 F01 III

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010
Penalty
Initial $100
Recent events (2)
  • — I (O)
  • — Z (O) $100.00

1910.142 H01

Other-than-serious 2 instances 18 exposed
Issued
Jan 25, 2010
Abate by
Feb 2, 2010