Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DUBOSE STRAPPING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DUBOSE STRAPPING, INC. in 906 INDUSTRIAL DRIVE, CLINTON, NC 28328 (NAICS 332999). OSHA activity number 313823205.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dubose Strapping, INC. — free Get an email when a new federal OSHA severe-injury report for Dubose Strapping, INC. is published. One employer, no account, unsubscribe in one click.
Site address
906 INDUSTRIAL DRIVE
City
CLINTON
State
NC
ZIP
28328
Mailing
POST OFFICE BOX 819, CLINTON, NC 28328
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
SIC code (legacy)
3499
Employees
75
Ownership type
A
Industry flags
Manufacturing safety.

10 citations on file for this inspection.

95012901

Serious 1 instance 8 exposed
Issued
Apr 12, 2010
Abate by
Apr 15, 2010
Penalty
Initial $3,500 · Current $3,500
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish each of his employees conditions of employment
and a place of employment free
from recognized hazards that were causing or likely to cause death or
serious physical harm to employees in
that employees were exposed to a potentially large fire from combustible
vapors or for the potential for
combustible residue buildup within the exhaust system, (duct and at the
duct intake, hood, enclosure or
canopy), without an automatic extinguishing system.
a)facility, SP-1, 2, and 3 - the exhaust hoods, duct intakes, ducts,
enclosures or canopy was not
provided with an automatic extinguishing system. This condition resulted
in a large fire within
the duct system on 1/21/10.
ABATEMENT NOTE:
1)Among other methods, one feasible and acceptable abatement method to
correct these hazards
is to provide an automatic extinguisher system within the exhaust system,
(duct and at the duck
intake, hood, enclosure, or canopy).
Reference:National Fire Protection Association (NFPA); NFPA 9, section 9,
Fire Protection -
Standard for Exhaust System for Air Conveying of Vapors, Gases, Mist, and
Noncombustible Particulate Solids
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

95012901

Serious 3 instances 3 exposed
Issued
Apr 12, 2010
Abate by
Apr 15, 2010
Penalty
Initial $3,500 · Current $3,500
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The
employer did not furnish each of his employees conditions of employment
and a place of employment free
from recognized hazards that were causing or likely to cause death or
serious physical harm to employees in
that employees were exposed to frequent fires caused by no testing,
inspection or routine maintenance on the
exhaust system, ( duct, duct intake, hood, enclosure, or canopy).
a)facility, SP-1,2,and 3 - exhaust system was not tested, and no routine
maintenance was
performed to ensure safe operating conditions of the exhaust system.
b)facility, SP-1,2,and 3 - exhaust system components, (duct and duct
intake.
hood, enclosure, or
canopy) were not inspected monthly.
c)facility, SP-1,2,and 3 - exhaust system was not tested annually to
demonstrate continued
performance.
ABATEMENT NOTE:
1)Among other methods, one feasible and acceptable abatement method to
correct these hazards
is to test, inspect, and to perform routine maintenance on exhaust system
for a safe operating
condition.
Reference:   National Fire Protection Association (NFPA) ; NFPA 91 chapter
10 Testing and
Maintenance, and section 10.4 System Inspection - Standard for Exhaust
Systems for
Air Conveying of Vapors, Gases, Mist, and Noncombustible Particulate
Solids- 2010
Edition
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

95012901

Serious 3 instances 8 exposed
Issued
Apr 12, 2010
Abate by
Apr 15, 2010
Penalty
Initial $3,500 · Current $3,500
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health
Act of North Carolina:  The
employer did not furnish each of his employees conditions of employment
and a place of employment free
from recognized hazards that were causing or likely to cause death or
serious physical harm to employees due
to electric shock hazards and struck by hazards due to improper
maintenance and cleaning operations of the
strip-paint drying oven:
a)facility, SP-1, 2,and 3 - no daily inspection for proper operating
conditions and for obvious
deterioration were conducted on the ovens.
b)facility, SP-1, 2,and 3 - water sprinkler system was provided as a fire
extinguishing system for
the high voltage electric powered ovens. This condition creates a shock
hazard for employees
during a fire emergency.
c)facility, SP-1, 2,and 3 - compressed air was used to clean paint residue
off the ovens
components, causing a high velocity dust that could penetrate the eyes.
ABATEMENT NOTE:
1)Among other methods, one feasible and acceptable abatement method to
correct these hazards
is to provide proper procedures for personnel performing maintenance on
the ovens.
Reference:Elotherm, Operating Instruction Securitys Strip-paint drying
Equipment - section 1.8,
Information on hazards residual risks, 1.13 Maintenance.
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

1910.147 C04 I

Serious 1 instance 5 exposed
Issued
Apr 12, 2010
Abate by
May 27, 2010
Penalty
Initial $3,500 · Current $3,500
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

1910.147 C05 II

Deleted Serious 1 instance 5 exposed
Issued
Apr 12, 2010
Abate by
Apr 15, 2010
Penalty
Initial $3,500 · Current $3,500
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

1910.147 C05 IIB

Serious 1 instance 5 exposed
Issued
Apr 12, 2010
Abate by
Apr 15, 2010
Penalty
Current $3,500
Recent events (2)
  • — I (S) $3500.00
  • — Z (S)

1910.147 C07 I

Deleted Serious 1 instance 5 exposed
Issued
Apr 12, 2010
Abate by
May 6, 2010
Penalty
Initial $3,500 · Current $3,500
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

1910.242 B

Serious 1 instance 5 exposed
Issued
Apr 12, 2010
Abate by
Apr 15, 2010
Penalty
Initial $2,000 · Current $2,000
Recent events (2)
  • — I (S) $2000.00
  • — Z (S) $2000.00

1910.132 F01

Deleted Serious 1 instance 5 exposed
Issued
Apr 12, 2010
Abate by
May 6, 2010
Penalty
Initial $2,000 · Current $2,000
Recent events (2)
  • — I (S) $2000.00
  • — Z (S) $2000.00

1910.133 A01

Serious 1 instance 5 exposed
Issued
Apr 12, 2010
Abate by
Apr 15, 2010
Penalty
Initial $2,000 · Current $2,000
Recent events (2)
  • — I (S) $2000.00
  • — Z (S) $2000.00

View Dubose Strapping, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313823205.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.