CLINTON, NC —
OSHA Inspection: DUBOSE STRAPPING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DUBOSE STRAPPING, INC. in 906 INDUSTRIAL DRIVE, CLINTON, NC 28328 (NAICS 332999). OSHA activity number 313823205.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DUBOSE STRAPPING, INC.
- Site address
- 906 INDUSTRIAL DRIVE
- City
- CLINTON
- State
- NC
- ZIP
- 28328
- Mailing
- POST OFFICE BOX 819, CLINTON, NC 28328
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- SIC code (legacy)
- 3499
- Employees
- 75
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
10 citations on file for this inspection.
95012901
- Issued
- Apr 12, 2010
- Abate by
- Apr 15, 2010
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a potentially large fire from combustible vapors or for the potential for combustible residue buildup within the exhaust system, (duct and at the duct intake, hood, enclosure or canopy), without an automatic extinguishing system. a)facility, SP-1, 2, and 3 - the exhaust hoods, duct intakes, ducts, enclosures or canopy was not provided with an automatic extinguishing system. This condition resulted in a large fire within the duct system on 1/21/10. ABATEMENT NOTE: 1)Among other methods, one feasible and acceptable abatement method to correct these hazards is to provide an automatic extinguisher system within the exhaust system, (duct and at the duck intake, hood, enclosure, or canopy). Reference:National Fire Protection Association (NFPA); NFPA 9, section 9, Fire Protection - Standard for Exhaust System for Air Conveying of Vapors, Gases, Mist, and Noncombustible Particulate Solids
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
95012901
- Issued
- Apr 12, 2010
- Abate by
- Apr 15, 2010
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to frequent fires caused by no testing, inspection or routine maintenance on the exhaust system, ( duct, duct intake, hood, enclosure, or canopy). a)facility, SP-1,2,and 3 - exhaust system was not tested, and no routine maintenance was performed to ensure safe operating conditions of the exhaust system. b)facility, SP-1,2,and 3 - exhaust system components, (duct and duct intake. hood, enclosure, or canopy) were not inspected monthly. c)facility, SP-1,2,and 3 - exhaust system was not tested annually to demonstrate continued performance. ABATEMENT NOTE: 1)Among other methods, one feasible and acceptable abatement method to correct these hazards is to test, inspect, and to perform routine maintenance on exhaust system for a safe operating condition. Reference: National Fire Protection Association (NFPA) ; NFPA 91 chapter 10 Testing and Maintenance, and section 10.4 System Inspection - Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mist, and Noncombustible Particulate Solids- 2010 Edition
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
95012901
- Issued
- Apr 12, 2010
- Abate by
- Apr 15, 2010
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees due to electric shock hazards and struck by hazards due to improper maintenance and cleaning operations of the strip-paint drying oven: a)facility, SP-1, 2,and 3 - no daily inspection for proper operating conditions and for obvious deterioration were conducted on the ovens. b)facility, SP-1, 2,and 3 - water sprinkler system was provided as a fire extinguishing system for the high voltage electric powered ovens. This condition creates a shock hazard for employees during a fire emergency. c)facility, SP-1, 2,and 3 - compressed air was used to clean paint residue off the ovens components, causing a high velocity dust that could penetrate the eyes. ABATEMENT NOTE: 1)Among other methods, one feasible and acceptable abatement method to correct these hazards is to provide proper procedures for personnel performing maintenance on the ovens. Reference:Elotherm, Operating Instruction Securitys Strip-paint drying Equipment - section 1.8, Information on hazards residual risks, 1.13 Maintenance.
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
1910.147 C04 I
- Issued
- Apr 12, 2010
- Abate by
- May 27, 2010
- Penalty
- Initial $3,500 · Current $3,500
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
1910.147 C05 II
- Issued
- Apr 12, 2010
- Abate by
- Apr 15, 2010
- Penalty
- Initial $3,500 · Current $3,500
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
1910.147 C05 IIB
- Issued
- Apr 12, 2010
- Abate by
- Apr 15, 2010
- Penalty
- Current $3,500
Recent events (2)
- — I (S) $3500.00
- — Z (S)
1910.147 C07 I
- Issued
- Apr 12, 2010
- Abate by
- May 6, 2010
- Penalty
- Initial $3,500 · Current $3,500
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
1910.242 B
- Issued
- Apr 12, 2010
- Abate by
- Apr 15, 2010
- Penalty
- Initial $2,000 · Current $2,000
Recent events (2)
- — I (S) $2000.00
- — Z (S) $2000.00
1910.132 F01
- Issued
- Apr 12, 2010
- Abate by
- May 6, 2010
- Penalty
- Initial $2,000 · Current $2,000
Recent events (2)
- — I (S) $2000.00
- — Z (S) $2000.00
1910.133 A01
- Issued
- Apr 12, 2010
- Abate by
- Apr 15, 2010
- Penalty
- Initial $2,000 · Current $2,000
Recent events (2)
- — I (S) $2000.00
- — Z (S) $2000.00
More inspections at Dubose Strapping, INC.
View Dubose Strapping, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313823205.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.