WILLIAMSTON, NC —
OSHA Inspection: NORTH CAROLINA MEAT PLANT L.L.C. DBA BIG CITY GYRO
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of NORTH CAROLINA MEAT PLANT L.L.C. DBA BIG CITY GYRO in 223 NORTH MCCASKEY ROAD, WILLIAMSTON, NC 27892 (NAICS 424420). OSHA activity number 313827941.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTH CAROLINA MEAT PLANT L.L.C. DBA BIG CITY GYRO
- Site address
- 223 NORTH MCCASKEY ROAD
- City
- WILLIAMSTON
- State
- NC
- ZIP
- 27892
- Mailing
- 60 TRIANGLE BLVD, CARLSTADT, NJ 07072
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424420
- SIC code (legacy)
- 5141
- Employees
- 15
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
22 citations on file for this inspection.
95012901
- Issued
- Apr 20, 2010
- Abate by
- Apr 23, 2010
- Penalty
- Initial $1,400 · Current $1,400
0170
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to unlabeled anhydrous ammonia refrigeration piping systems. a)facility - for employees exposed to anhydrous ammonia piping systems that the employer did not ensure were adequately labeled with the contents and/or direction of flow. Abatement Notes: Anhydrous ammonia refrigeration piping systems shall be labeled with the contents and direction of flow. Label all of the pipes in accordance with ANSI 13.1-1975: Scheme for the Identification of Piping Systems. CHAPTER XHAPTER
95012901
- Issued
- Apr 20, 2010
- Abate by
- Apr 23, 2010
- Penalty
- Initial $1,400 · Current $1,400
0170
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to anhydrous ammonia refrigeration piping systems. a)facility - for employees exposed to anhydrous ammonia refrigeration piping systems and the employer did not obtain and maintain all essential records and documentation relevant to the system for those performing inspection, maintenance, and operation. Abatement Notes: Ensure that essential records and documentation pertaining to the anhydrous ammonia refrigeration system are maintained in accordance with the International Instituted of Ammonia Refrigeration (IIAR) Start-up, Inspection, and Maintenance of Ammonia Mechanical Refrigerating Systems Bulletin 110 (3/93), Section 4.0 (Records). "All essential records and documentation relevant to the system shall be obtained by the user and maintained by the user in a safe place and be readily available for examination so that the standards and details to which the system was designed are available to those concerned with inspection, maintenance, and operation."
95012901
- Issued
- Apr 20, 2010
- Abate by
- Apr 23, 2010
- Penalty
- Initial $1,400 · Current $1,400
0170
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to lack of inspections and maintenance programs for the equipment comprising the anhydrous ammonia refrigeration system. a)facility - for employees exposed to the anhydrous ammonia refrigeration system and the employer did not ensure that the system was inspected and maintained in accordance with the supplier's instructions. Abatement Notes: For all abatement notes below, follow guidelines regarding inspections and maintenance in accordance with the International Instituted of Ammonia Refrigeration (IIAR) Start-up, Inspection, and Maintenance of Ammonia Mechanical Refrigerating Systems Bulletin 110 (3/93), Section 6.0 (Inspection and Maintenance). Section 6.1: "For any particular refrigerating system, the inspection and maintenance program shall account for specific recommendations for the equipment comprising that system, found in the supplier's instruction manual and relevant supplementary information. The type and frequency of inspection and maintenance will also depend on the effectiveness of previous maintenance, the age of the system, the environment in which the system in located, and the duty of the system." b)facility - for employees exposed to anhydrous ammonia refrigeration system and the employer did not ensure that the compressor was isolated and inspected at a minimum of every three months. Abatement Notes: Section 6.3.2 Major Inspection and Maintenance: "At least every three months, the compressor motive power shall be securely isolated and the mechanical condition of the drive shall be inspected." "At least annually, in addition to the above, the drive alignment and the condition and tightness of the foundation bolts shall be checked. Where applicable, the drive shaft end float shall be checked." c) facility - for employees exposed to anhydrous ammonia refrigeration system and the employer did not ensure that the 7,500 lb. vessel and heat exchangers were inspected at a minimum of once every 12 months. Abatement Notes: Section 6.4.3 Annual Inspection: "Where vessels and heat exchangers are in daily use, a detailed examination of the external surface or of the insulation applied to the external surface of such vessels and heat exchangers shall be made at intervals of not more than 12 months." d)facility - for employees exposed to anhydrous ammonia refrigeration system and the employer did not ensure that the uninsulated and insulated piping was inspected at a minimum of once every 12 months for damage and/or deterioration. Abatement Notes: Section 6.7.1 Uninsulated Piping: "All uninsulated piping and associated components such as flanges and supports shall be inspected annually for any damage to or deterioration of the piping or its protective finish." Section 6.7.2 Insulated Piping: "At least as part of the annual piping inspection, but preferably more frequently, the external condition of the insulation and supports shall be inspected."
1910.23 C01
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
- Penalty
- Initial $1,400 · Current $1,400
1910.106 B02 VIIA
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
- Penalty
- Initial $300 · Current $300
1910.120 Q01
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
- Penalty
- Initial $1,400 · Current $1,400
0170
1910.120 Q04
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.120 Q05
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.120 Q06 IA
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.120 Q10
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.120 Q11 II
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.132 A
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
- Penalty
- Initial $1,400 · Current $1,400
0170
1910.132 D01
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.132 F01
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.134 A02
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
- Penalty
- Initial $1,400 · Current $1,400
0170
1910.146 C01
- Issued
- Apr 20, 2010
- Abate by
- Apr 23, 2010
- Penalty
- Initial $1,400 · Current $1,400
1910.147 C01
- Issued
- Apr 20, 2010
- Abate by
- Apr 23, 2010
- Penalty
- Initial $1,400 · Current $1,400
0170
1910.1200 E01
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
- Penalty
- Initial $1,400 · Current $1,400
0170
1910.1200 E01 I
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.1200 E02
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.1200 H01
- Issued
- Apr 20, 2010
- Abate by
- May 14, 2010
0170
1910.141 A03 I
- Issued
- Apr 20, 2010
- Abate by
- Jun 7, 2010
More inspections at North Carolina Meat Plant L.L.C. DBA BIG City Gyro
View North Carolina Meat Plant L.L.C. DBA BIG City Gyro's full OSHA safety record →
More inspections in this industry (NAICS 424420)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313827941.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.