Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHRISTIAN JACOB HOMES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHRISTIAN JACOB HOMES, LLC in 128 WOOL STREET, BARRINGTON, IL 60010 (NAICS 238130). OSHA activity number 313847972.

Watch Christian Jacob Homes, LLC — free Get an email when a new federal OSHA severe-injury report for Christian Jacob Homes, LLC is published. One employer, no account, unsubscribe in one click.
Site address
128 WOOL STREET
City
BARRINGTON
State
IL
ZIP
60010
Mailing
117 SOUTH COOK STREET #335, BARRINGTON, IL 60010
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
6
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 23, 2009
Abate by
Dec 4, 2009
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to struck by/caught in between hazards posed by the wooden
roof
truss collapse
during installation:
a)On October 13, 2009 at the jobsite located at 128 Wool Street in
Barrington, Illinois,
60010, employees of Christian Jacob Homes, LLC were exposed to being
struck and
caught in between metal plate connected wood trusses that were not braced,
installed and
loaded in accordance to the manufacturer's specifications.
1.There were no top chord lateral braces installed on the trusses.
2.There were no ground braces installed.
3.There were no top chord diagonal braces installed on the trusses.
4.Loads were placed on the wooden trusses before they were fully braced.
Feasible and acceptable methods of abatement to correct this hazard would
be to: 1) Follow the
manufacturer's specifications for erection and temporary bracing of wood
trusses or 2) Conform
to the Building Component Safety Information (BCSI) 1-03:  Guide to Good
Practice for
Handling, Installing & Bracing of Metal Plate Connected Wood Trusses
issued by The Wood
Truss Council of America and Truss Plate Institute.
**In accordance with 29 CFR 1903.19(d), abatement certification is
required for this violation
(using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition,
documentation demonstrating that abatement is complete must be included
with your
certification.  This documentation may include, but is not limited to,
evidence of the purchase
or repair of the equipment, photographic or video evidence of abatement,
or other written
records.**
Recent events (3)
  • — A (S) $1500.00
  • — I (S) $875.00
  • — Z (S) $1500.00

1926.20 B01

Serious Gravity 03 1 instance 5 exposed
Issued
Nov 23, 2009
Abate by
Jan 15, 2010
Penalty
Initial $750 · Current $750
Recent events (3)
  • — A (S) $750.00
  • — I (S) $400.00
  • — Z (S) $750.00

1926.20 B02

Serious Gravity 03 1 instance 5 exposed
Issued
Nov 23, 2009
Abate by
Jan 15, 2010
Recent events (2)
  • — I (S)
  • — Z (S)

1926.21 B02

Serious Gravity 03 1 instance 5 exposed
Issued
Nov 23, 2009
Abate by
Jan 15, 2010
Recent events (2)
  • — I (S)
  • — Z (S)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313847972.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.