BARRINGTON, IL —
OSHA Inspection: CHRISTIAN JACOB HOMES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHRISTIAN JACOB HOMES, LLC in 128 WOOL STREET, BARRINGTON, IL 60010 (NAICS 238130). OSHA activity number 313847972.
Where did this inspection happen?
- Establishment
- CHRISTIAN JACOB HOMES, LLC
- Site address
- 128 WOOL STREET
- City
- BARRINGTON
- State
- IL
- ZIP
- 60010
- Mailing
- 117 SOUTH COOK STREET #335, BARRINGTON, IL 60010
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- SIC code (legacy)
- 1751
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 23, 2009
- Abate by
- Dec 4, 2009
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by/caught in between hazards posed by the wooden roof truss collapse during installation: a)On October 13, 2009 at the jobsite located at 128 Wool Street in Barrington, Illinois, 60010, employees of Christian Jacob Homes, LLC were exposed to being struck and caught in between metal plate connected wood trusses that were not braced, installed and loaded in accordance to the manufacturer's specifications. 1.There were no top chord lateral braces installed on the trusses. 2.There were no ground braces installed. 3.There were no top chord diagonal braces installed on the trusses. 4.Loads were placed on the wooden trusses before they were fully braced. Feasible and acceptable methods of abatement to correct this hazard would be to: 1) Follow the manufacturer's specifications for erection and temporary bracing of wood trusses or 2) Conform to the Building Component Safety Information (BCSI) 1-03: Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses issued by The Wood Truss Council of America and Truss Plate Institute. **In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.**
Recent events (3)
- — A (S) $1500.00
- — I (S) $875.00
- — Z (S) $1500.00
1926.20 B01
- Issued
- Nov 23, 2009
- Abate by
- Jan 15, 2010
- Penalty
- Initial $750 · Current $750
Recent events (3)
- — A (S) $750.00
- — I (S) $400.00
- — Z (S) $750.00
1926.20 B02
- Issued
- Nov 23, 2009
- Abate by
- Jan 15, 2010
Recent events (2)
- — I (S)
- — Z (S)
1926.21 B02
- Issued
- Nov 23, 2009
- Abate by
- Jan 15, 2010
Recent events (2)
- — I (S)
- — Z (S)