Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: BROKEN CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BROKEN CONSTRUCTION, INC. in 14417 ARGYLE MANOR, SUN CITY, FL 33570 (NAICS 238160). OSHA activity number 313853459.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Broken Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Broken Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
14417 ARGYLE MANOR
City
SUN CITY
State
FL
ZIP
33570
Mailing
3461 MAPLE DR, MULBERRY, FL 33860
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
SIC code (legacy)
1761
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 1, 2009
Abate by
Oct 7, 2009
Penalty
Initial $1,500 · Current $1,125 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that:
a) Employees engaged in truss erection were exposed a struck by hazard;
roof truss
over 40 feet long were not rigged for hoisted in accordance with
recognized industry
practices. At the site; employees were exposed to the hazard of being
struck by
wooden roof truss forty foot long.  The truss were hoisted using a chain
sling; the use
of a chain sling on wooden truss over 30 feet long may cause lateral
bending, causing
the truss to break thereby striking any exposed employees.
One feasible and acceptable method to correct this hazard would be to use
a spreader bar or
stiff back in accordance with the Building Component Safety Information,
Guide to Good
Practice for Handling, Installing, Restraining and Bracing of Metal plate
Wood Trusses.
Recent events (2)
  • · I (S) $1125.00
  • · Z (S) $1500.00

1926.501 B13

Serious Gravity 04 1 instance 4 exposed
Issued
Oct 1, 2009
Abate by
Oct 7, 2009
Penalty
Initial $750 · Current $563 Reduced
Recent events (2)
  • · I (S) $562.50
  • · Z (S) $750.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 313853459.