KANKAKEE, IL —
OSHA Inspection: BUNGE NORTH AMERICA DBA BUNGE MILLING, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BUNGE NORTH AMERICA DBA BUNGE MILLING, INC. in 1580 GRINNELL ROAD, KANKAKEE, IL 60901 (NAICS 311211). OSHA activity number 313939977.
Where did this inspection happen?
- Establishment
- BUNGE NORTH AMERICA DBA BUNGE MILLING, INC.
- Site address
- 1580 GRINNELL ROAD
- City
- KANKAKEE
- State
- IL
- ZIP
- 60901
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311211
- SIC code (legacy)
- 2041
- Employees
- 91
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 28, 2011
- Abate by
- Apr 14, 2011
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to the hazard of fire and explosion because methods and practices were not utilized to prevent air-material separators (dust collectors) from explosion or prevent propagation of fire/explosion from air-material separators into areas that were or could have been occupied by employees: Specialty Building: On or about October 10, 2010, employees required to perform corn milling operations were exposed to the hazard of fire and explosion because the indoor filter- receiver material-air separator I.P.S.C. (Industrial Process Systems and Components) Co. Inc. Model No. 319-0137 downstream to the Sturtevant Model No.3 NSP Powderizer (classifier-grinder) was not provided with either fire/explosion prevention or protection controls. The filter-receiver material-air separator was used to collect combustible corn flour dust. Among other methods, a feasible method to correct this hazard is to comply with the National Fire Protection Agency (NFPA) 61 "Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities (2008)", including, but not limited to: The filter-receiver material-air separator should be protected by containment, suppression, inerting or explosion venting as described in Sections 11.4.1 and 6.3.1 of the 2008 NFPA 61 standard. NOTE: 29 CFR 1903.19 REQUIRES THAT YOU PROVIDE CERTIFICATION AND DOCUMENTATION OF ABATEMENT FOR THIS ITEM.
Recent events (2)
- — I (S) $7000.00
- — Z (S) $7000.00
5(a)(1)
- Issued
- Feb 28, 2011
- Abate by
- Apr 14, 2011
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to the hazard of fire and explosion because methods and practices were not utilized to prevent air- material separators (dust collectors) from explosion or prevent propagation of fire/explosion from air-material separators into areas that were or could have been occupied by employees: a)Specialty Packaging Area/Tower Area: On or about October 10, 2010, employees required to perform corn milling operations were exposed to the hazard of fire and explosion because the indoor Micro-D Pulsaire North Filter 034-202 dust collector was not provided with either fire/explosion prevention or protection controls. The dust collector was used to collect fugitive combustible corn dust. b)Specialty Packaging Area/Tower Area: On or about October 10, 2010, employees required to perform corn milling operations were exposed to the hazard of fire and explosion because the indoor Micro-D Pulsaire North Filter 034-202 dust collector unsafely discharged recycled air back into the facility. The dust collector was used to collect fugitive combustible corn dust. c)Specialty Building: On or about October 10, 2010, employees required to perform corn milling operations were exposed to the hazard of fire and explosion because the indoor Flex- Kleen dust collector was not provided with either fire/explosion prevention or protection controls. The dust collector was used to collect fugitive combustible corn dust. Among other methods, a feasible method to correct this hazard is to comply with the National Fire Protection Agency (NFPA) 61 "Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities (2008)", including, but not limited to: 1.Protect air-material separators (dust collectors) by containment, suppression, inerting or explosion venting as described in Sections 10.4.3 and 6.3.1 of the 2008 NFPA 61 standard. 2.Discharge air from dust collectors to the outside or install a high-speed abort gate activated by a spark detector sufficiently fast to intercept and divert any burning material to atmosphere before it can enter the facility through the recycled air duct to comply with Section 10.4.12.1 of the 2008 NFPA 61 standard. NOTE: 29 CFR 1903.19 REQUIRES THAT YOU PROVIDE CERTIFICATION AND DOCUMENTATION OF ABATEMENT FOR THIS ITEM.
Recent events (2)
- — I (S) $7000.00
- — Z (S) $7000.00
1910.272 J01
- Issued
- Feb 28, 2011
- Abate by
- Apr 14, 2011
- Penalty
- Initial $5,000 · Current $5,000
Recent events (2)
- — I (S) $5000.00
- — Z (S) $5000.00
1910.272 M01 I
- Issued
- Feb 28, 2011
- Abate by
- Apr 14, 2011
- Penalty
- Initial $7,000 · Current $7,000
Recent events (2)
- — I (S) $7000.00
- — Z (S) $7000.00
1910.272 M01 II
- Issued
- Feb 28, 2011
- Abate by
- Apr 14, 2011
Recent events (2)
- — I (S)
- — Z (S)
1910.272 M03
- Issued
- Feb 28, 2011
- Abate by
- Apr 14, 2011
Recent events (2)
- — I (S)
- — Z (S)
5(a)(1)
- Issued
- Feb 28, 2011
- Abate by
- Apr 14, 2011
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to the hazard of fire and explosion because methods and practices were not utilized to prevent air-material separators (dust collectors) from explosion or prevent propagation of fire/explosion from air-material separators into areas that were or could have been occupied by employees: Specialty Building: On or about October 10, 2010, employees required to perform corn milling operations were exposed to the hazard of fire and explosion because the indoor filter- receiver material-air separator I.P.S.C. (Industrial Process Systems and Components) Co. Inc. Model No. 319-0137 downstream to the Sturtevant Model No.3 NSP Powderizer (classifier-grinder) was not provided with either fire/explosion prevention or protection controls. The filter-receiver material-air separator was used to collect combustible corn flour dust. Among other methods, a feasible method to correct this hazard is to comply with the National Fire Protection Agency (NFPA) 61 "Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities (2008)", including, but not limited to: The filter-receiver material-air separator should be protected by containment, suppression, inerting or explosion venting as described in Sections 11.4.1 and 6.3.1 of the 2008 NFPA 61 standard. NOTE: 29 CFR 1903.19 REQUIRES THAT YOU PROVIDE CERTIFICATION AND DOCUMENTATION OF ABATEMENT FOR THIS ITEM.
Recent events (2)
- — I (S) $7000.00
- — Z (S) $7000.00
1910.272 M01 I
- Issued
- Feb 28, 2011
- Abate by
- Dec 31, 2012
- Penalty
- Initial $7,000
Recent events (2)
- — I (S)
- — Z (S) $7000.00
1910.272 M03
- Issued
- Feb 28, 2011
- Abate by
- Dec 31, 2012
Recent events (2)
- — I (S)
- — Z (S)
1910.272 M01 II
- Issued
- Feb 28, 2011
- Abate by
- Dec 31, 2012
Recent events (2)
- — I (S)
- — Z (S)
More inspections at Bunge North America DBA Bunge Milling, INC.
View Bunge North America DBA Bunge Milling, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311211)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 313939977.