Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUTOBAN EXCELLENCE

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AUTOBAN EXCELLENCE in 163 NORTH GIBSON ROAD, HENDERSON, NV 89104 (NAICS 811198). OSHA activity number 313974982.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Autoban Excellence — free Get an email when a new federal OSHA severe-injury report for Autoban Excellence is published. One employer, no account, unsubscribe in one click.
Establishment
AUTOBAN EXCELLENCE
Site address
163 NORTH GIBSON ROAD
City
HENDERSON
State
NV
ZIP
89104
Mailing
163 NORTH GIBSON ROAD, HENDERSON, NV 89104
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811198
SIC code (legacy)
7539
Employees
4
Ownership type
A
Industry flags
Manufacturing health.

2 citations on file for this inspection.

618037501

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 12, 2010
Abate by
Oct 15, 2010
Penalty
Initial $750 · Current $750
Nevada Revised Statute 618.375(1): Every employer did not furnish employment and
a place of employment which was free from recognized hazards that were causing
or were likely to cause death or serious physical harm to his employees: (a) Aut
obahn Excellence: Two mechanics were exposed to injuries resulting form being st
ruck by fragments of schedule 40 Polyvinylchloride (PVC) pipe used to distribute
up to 100 psi of compressed air, which is not recommended by the manufacturer b
ecause of heat breakdown and potential fragmentation. One feasible and acceptabl
e method, among others, would be to replace the PVC pipe with a pipe capable of
withstanding compressed air distribution. Reference: PVC manufacturer's data cau
tion and warning notices which state: "Do not use compressed air or gas for pres
sure testing", PVC and CPVC products are not recommended
for use in compressed air or gas systems", and "The manufacturer does not recomm
end its PVC or CPVC products for use in air or compressed gas systems. PVC and C
PVC pipe, fittings, and valves are excellent products for the transport of water
and corrosive chemicals. But there are a number of other piping products that a
re expecially designed and suited for compressed air and gases."sed

1910.1200 E01

Serious Gravity 03 1 instance 2 exposed
Issued
Oct 12, 2010
Abate by
Nov 14, 2010
Penalty
Initial $750 · Current $750

Hazardous substances 00400435138024602590

View Autoban Excellence's full OSHA safety record →